WiNRADiO G33DDC HF Receiver
82
Note that the
MW filter
and
RF filter
buttons are mutually exclusive (the MW
filter actually uses a subset of the RF filter).
When the RF filter is engaged, its passband is indicated by a greyed out area
visible in the spectrum.
S-meter
The WiNRADiO
Excalibur Pro
receiver is equipped with a very sensitive and
selective
Signal Strength Meter
(
S-meter
) which makes it possible to
measure peak or RMS signal level in dBm, µV or S-units, within the
demodulator filter passband. The measurement units are selected by
appropriately marked buttons at the bottom of the display.
The S-meter also shows the currently selected value of the squelch (the red
section at the bottom side of the scale) when the squelch is enabled. When the
signal strength falls under the squelch level (i.e. the needle falls in the red
region and turns red also), the receiver audio will be muted and the word
“
Squelched
” will appear inside the S-meter.
The squelch value is always indicated in dBm (even if the signal strength is
displayed in S-units or microvolts).
The
Peak
and
RMS
buttons select between peak and RMS values. The
AVG
button applies a floating average with a one second time interval to smooth the
S-meter movement.
The S-meter is very selective, and acts only upon signals within the selected
demodulator bandwidth (gray-shaded area in the demodulator spectrum
display).
Please note that the actions of both the attenuator and preamplifier are
compensated for by the S-meter. This means that the S-meter always