Radionics D9000 Series Скачать руководство пользователя страница 11

D9000/D7000 Series Installation and Troubleshooting Quick Reference

Page  11

33317D  4/97

P

P

P

P

S

D122 DUAL

BATTERY HARNESS

ARMING STATION

TO RJ31X FOR

PRIMAR Y
PHONE LINE

TO RJ31X FOR
SECONDARY

PHONE LINE

16 VAC
40 VA
60 HZ
TRANSFORMER

AS 

REQUIRED

D1255

UP TO EIGHT
SUPERVISED

D105 F  EOL

DE VICE 

G

N

D

 

A

U

X

O

U

T

IN

D928

D105  BL
EOL DEVICE

(FOR  TYPI CAL BURGLAR 
ALARM APPLICATIONS)

SUITABLE FOR V ALVE  TAMPER 

AND OTHER  TY PES OF 

EXTI NGUISHING SY STEM 

SUPER VIS ION.

TYPICAL  I NI TIATING DEV ICES  ARE 
DOOR CONTACTS  NO/ NC, FLOOR 
MATS, MOTION SENSORS,  GLAS S 
BREAK DETECT ORS, ETC.

D

A

T

A

A

U

X

G

N

D

D8129 

OCTORELAY

D8125 POPEX 1

P

P

S

S

- +

- +

D125B

1 10 3 4 2

or
5

L

O

O

P
A

D129

6 7 5 8 9

1
2
3
4

10 11 12 13

D129 PROVIDES OPTIONAL
WATERFLOW ALARM RETARD 
FEATURE. NOT  SUITABLE FOR 2-
WIRE SMOKE DETECT ORS. NOTE: 
USE ZERO RETARD EXCEPT  FOR 
WATERFLOW.

LOOP B

 D192C

P

P

S

S

+

-

ECL DEVICE 15-03130-001

LISTED  
AUDIBLE 

SIGNALING 
DEVICES 

RATED AT 10.2 
TO 13.8 VDC  
(DO NOT  USE 
VIBRATING 
TYPE HORNS)

AUX PWR

ALARM TRIG

COM

SUPV IN

ALARM CKT

P

-

-

+

D126

BATTERY

12V 7Ah

D126

BA TTERY

12V 7Ah

CONNECT UP

TO EIGHT

OCTORELAYS

IN

O

U

T

A

U

X

G

N

D

 

D8125 POPEX 2

P

S

P

S

-

+

-

+

D

A

T

A

A

U

X

G

N

D

D8129 OCTORELAY

OR D811 ARM STATUS RELAY

CONNECT UP

TO EIGHT

OCTORELAYS

P

S

P

S

P

P

J3

P

S

P

S

P

S

P

S

= POWER LIMITED

= SUPERVISED

D1640

D8132

BATTERY

CHARGER

D126

BATTERY

12V 7Ah

D126

BA TTERY

12V 7Ah

D8004 TRANSFORMER

ENCLOSURE. 
REQUIRED FOR NFP A
APPLICATIONS.

OR D811 ARM STA

PA

PR

+

P

5

9

1 0

1

4

2

Low Batter y

LEDs Off When Normal

E AR TH  G R O U N D

CO MM ON

CLA SS  2  T RAN SF OR ME R
16.5  VA C 4 0 VA   6 0 H Z
Part No . D1 64 0

In ter n al ly F use d - D o N ot Sho rt
Req u ire s U nsw i tch e d O ut let
Do N ot  Sh a re With  Oth e r Equ ipm ent

+  A UX  P O W E R

B ATTE RY  N E G ATIV E  O NL Y

M a x im um  C h arg in g

C u rre n t  1.4  A m p s.

PH O NE   MO N I TOR  S E LE CT

L o o p  S tart
G r o u nd  St ar t

TE L C O 
C ORD

PH ON E

L E D  

O N    WH EN
CO M M U NI C AT IN G
O F F   WH EN  ID LE  

W A R NIN G!
M ulti -Ba tter y  In s ta llation  Re qu ir e s
M ode l N o. D 12 2 D ual B atte ry  Har ne s s
Im pr o pe r  In s tallat ion Ca n B e a  Fi re  Ha zard .

Re q u i res
Re la y
#D 1 3 6
IN  J5

Ba tter y :   Re plac e  ev e ry  3 to
5 y ea rs w ith  M o de l D 126 ,12 V
7A m p  Hr  Le ad  A c id B att ery

O N - BOA R D P OIN TS

1. 0 K   R e s i sto r

Re q u i red  at  En d o f  Li n e

V OL TAG E   RA NG E S

O p e n                    3 .7  -  5.0 VD C
N or m a l               2 .0 -  3 .0 V D C
S h o rt                   0 .0 -  1 .3 V D C

P ER IP H ER AL  D E VI CE  W IR IN G

ZO NE X O U T  1

ZO N EX  IN  1

ZO NE X O U T  2  

ZO N EX  IN  2

ZO N E X P OW E R  +

Z ON EX   C O M MO N

O p e ra tion  M o n itor

P uls es  W he n N o rm al

Fli ck e r s  W h en  R ing ing  

PROG

CONN

R E D

Y E L L OW

G RE EN

B LA CK

1 7-0 582 3- 002

3 2

P OW ER  +

D AT A B U S  A

C O M MO N

R ED

GR OU ND
S TA R T

YE L

R E D

R e se t  P in

D is abl e A ll E x c e p t B a tte r y

C h arg ing   A n d  P ro gr am m i ng

GR N

ST E A D Y  O R  
PU L S E

+

Charging Status 

N.F.P.A. 

Style 3.5 

Signaling

Line 

Circuits

P O W E R  S U P PLY  R E Q UI RE M E NT S
T h e P ow e r  S u pp ly  P ro v id es   a M ax im um  of  1. 4 A m p s  F or  Th e C on tr o l a nd
A ll A c c e s so ry   De v ic es   F o r S y s t em  Lo a d ing . S ee  O p era t io n- Ins tallatio n M a nua l
#7 4 -0 76 2 9- 00 0.
A ll E x ter nal  Co nn e c tion s  E x c e p t Te rm ina l         ( B a tte ry   P o s itiv e)  A r e I nh e re ntly
P o w e r L im i ted .
R e qu irem en ts  F o r  B att ery  S t an d by  T im e  M ay  Re du c e  A ll ow abl e O ut put . 
C A U T IO N :  S e e M an ua l F or P o wer   R equ ire m e nts  R ela tin g to  Te r m in als

R ef ere n ce  M an ua l #7 4- 061 44 - 00 0  F or  S y s t em  W irin g D iag r a m    Is s ue  A

,

R ef ere n ce  M an ua l #7 3- 061 43 - 00 0  F or  C om pat ibl e S m o k e  De te cto rs

1 2

15

18

21

13

11

1 4

16

17

1 9

20

2 2

5

6

7

P ROGRAMMABLE

ALARM OUTPUTS

Ter minals

&

Requir es

Optional

D136 Relay 

in J1 & J9

7               8

P o in t 1

Po in t 2

P o i nt 3

Po in t  4

Po in t 5

Po i n t 6

P oi nt 7

Po in t 8

D ATA B U S  B

2 9

3 1

3 0

2 4

2 3

2 8

2 7

2 6

2 5

BAT TE R Y  PO S IT IV E O NL Y

+  A L TE R N ATE

S W IT CH ED  
A U X   PO WE R

+

3

6

7

8

Th is  E qu ipm en t sh ou ld  be i nst alle d in a cc o rda nc e w ith  the  NF P A  70  (N ationa l E lec tr ic  Code )
an d a pp lica ble  71  Ce ntr al S tat ion, 72  C hap ter  6 L oc al,  72  Ch apt er 8  R em ote  S t atio n,
74  Ho us eho ld  F ire  (N ati ona l F ir e  pr otec tion  A s so cia tion , B att ery ma rc h  Pa rk ,  Qu inc y, M A   022 69 ).
Pr inte d info rm a tio n des c rib ing  pro pe r in s tallat ion,  op era tio n, t est ing , m ain ten anc e,  ev ac u atio n
pla nn ing  and r epa ir s erv ic e  is  to b e p ro vide d w ith  th is e qui pm ent .

D 94 12  Co n tr ol /C o m m u n ic ato r is  U L  L is te d  fo r  Ce ntra l S ta ti o n,  L oc al ,  R e m o te  S tat i on  an d  H o us e h o l d

Fir e A l ar m , a n d  C e ntra l S ta ti o n,  Lo c a l,  Po li ce  S ta tio n  C o nn ec t a n d  H ou se h o ld  Bu rgl a r  A la rm .

S

S

S

S

S

S

D9131A PARALLEL

PRINTER

INTERFACE

S

S

S

S

D 9112

D igi tal  A la rm , C om m uni c at or  Tra ns m it te r

Up to 119 D912
up to 6 4 D8127

Up to 119 D9127 U/T PO
up  to 64 D81 27 U/T POP

U p  to  1 4  D 8 1 2 8 C  O c to P O P ITs

U p  to  1 4  D 8 1 2 8 C  O cto P O P ITs

D9112 Control/Communicator

www.PDF-Zoo.com

firealarmresources.com

Содержание D9000 Series

Страница 1: ...icator 12 D7212Control Communicator 13 QuickReferenceTerminalDescription 14 Introduction This reference contains the very basic information a trained installer needs to install and troubleshoot a D900...

Страница 2: ...oint tested for 60 seconds After 60 seconds the display returns to the points to test message Extra Points display default text If you incorrectly set the switches on a POPIT to a point number that is...

Страница 3: ...NTESTED N EXT SERVICE WALK 246 PTS TO TEST 245 PTS TO TEST 244 PTS TO TEST POINT TEXT POINT TEXT POINT TEXT 1 PTS TO TEST 0 PTS TO TEST IDLE TEXT POINT TEXT Test a device Text displays 60 seconds Test...

Страница 4: ...d at the last address on the ZONEX bus Install a D8125 POPEX and D9127 POPITs for points 121 127 on ZONEX 1 and for points 241 247 on ZONEX 2 Sensor loop switch 1 to 8 is turned off on OctoPOPIT If th...

Страница 5: ...res input from all points in the same area programmed for sensor reset during sensor reset Two points are programmed with the same address Points programmed with the same address do not function corre...

Страница 6: ...d 24 share a common circuit breaker Check wiring and devices connected to these terminals for shorts or grounds If only one POPEX module is connected to the panel POPEX module may be incorrectly conne...

Страница 7: ...programmer connector J7 3 Check each conductor in the data power cord for continuity AC induction through the on board point sensor loops the DATA BUS or the ZONEX BUS 1 Verify a proper earth ground a...

Страница 8: ...contact your telephone company repair service Communications Failure Follow the Phone Line Trouble procedure to verify that there is no problem with the phone lines at the installation If the phone li...

Страница 9: ...s Can hear ring with test set at receiver location Line card in receiver may be faulty Review receiver manuals for trouble shooting procedures The D9412 D9112 reaches a busy signal for all ten attempt...

Страница 10: ...r t 0 0 1 3V DC PER IPH ERAL DE VICE W IR ING Z ONE X O UT 1 ZO NEX IN 1 Z ONE X O UT 2 ZO NEX IN 2 ZON EX P OWE R Z ONE X CO MM ON O p eratio n Mo nito r Puls es W he n No rma l F licke rs W h e n Ri...

Страница 11: ...UT 1 ZO NEX IN 1 ZO NE X O UT 2 ZO NEX IN 2 ZO NEX POW ER Z ON EX CO MMO N O p e ra tion M o n itor P uls es W he n N o rm al Fli cke rs W h en R ing ing PROG CONN RED YELLOW G RE EN B LA CK 1 7 0 58...

Страница 12: ...ZO NEX IN 2 ZO NEX PO WE R Z O NEX CO MMO N O p era tio n M o nit or P uls es W he n No rm al Fli cke rs W h e n R in gi ng PROG CONN RE D YELLO W GRE EN BLACK 1 7 058 23 0 02 3 2 PO W ER DATA BU S A...

Страница 13: ...ON EX IN 2 Z ON EX PO WE R ZO NEX CO MMO N Op erati on Mo nit or Pu lse s W h en No rm al F lick er s W h en Rin gi ng PROG CONN RE D Y EL LO W GREEN BLA CK 17 05 82 3 0 02 3 2 PO W ER DATA BU S A CO...

Страница 14: ...or alarm verification Shares circuit breaker with terminals 6 and 7 D136 Plug in Relay required Install a D136 in socket K1 for output at terminal 8 9 COMMON Terminal 9 is common for Auxiliary Power...

Отзывы: