Range:
150 meters (minimum) in free space.
RF RECEPTION
Alarm Signal Reception:
Turns on horn without red light flashing for 60 seconds
unless it receives an alarm cancel signal within that period.
Duration of House Code Mode:
15 minutes
RF VISUAL INDICATOR (Amber)
On Transmission:
Amber LED lights continuously for 1.5 to 3.5 seconds while
messages are being transmitted. The amber light also flashes after receipt of an
alarm cancel signal.
Low Battery Indication:
Amber light flashes every 10 second.
Size of System:
A maximum number of 12 Ei168 units can communicate together
on one system (however the range is likely to be the limiting factor in many cases)
Communication:
All units will communicate together as shipped. After a unit has
been house coded it will only communicate with other units house coded at the same
time. House coding is essential to prevent false alarms from neighbouring systems.
Entering House Code Mode:
Pressing and holding the House Code switch until
the amber light comes on puts the
RadioLINK
Base into house code mode.
House Code Mode:
The
RadioLINK
Base transmits and receives specific codes.
The amber light flashes once every 5 seconds for each unit s code it memorises
(including itself).
15