background image

© 2015 Radiodetection Ltd 

Section 1 - Preface 

 

Before you begin 

Thank  you  for  your  interest  in  Radiodetection’s 
RD8100

™ cable and pipe locator. 

The RD8100 delivers the latest in locating technology in 
a powerful yet ergonomic and light-weight design. 

Please  read  this  user  manual  in  its  entirety  before 
attempting to use the RD8100 system. 

Radiodetection  products,  including  this  manual,  are 
under  continuous  development.  The  information 
contained  within  is  accurate  at  time  of  publication; 
however  the  RD8100,  this  manual  and  all  its  contents 
are subject to change. 

Radiodetection Limited reserves the right to modify the 
product without notice and some product changes may 
have taken place after this user manual was published. 

Contact  your  local  Radiodetection  dealer  or  visit 

www.radiodetection.com

 for the latest information about 

the RD8100 product family, including this manual. 

1.1 Important notices 

General 

The performance of any cable and pipe locator may be 
affected  when  used  in  close  proximity  to  ferrous 
materials  such  as  manhole  covers,  steel-toe  boots, 
mobile phones and nearby vehicles. Keep a distance of 
one or two meters from these objects when taking critical 
measurements such as depth and current readings. 

This  instrument,  or  family  of  instruments,  will  not  be 
permanently  damaged  by  reasonable  electrostatic 
discharge and has been tested in accordance with IEC 
801-2. 

However, 

in 

extreme 

cases 

temporary 

malfunction may occur. If this happens, switch off, wait 
and switch on again. If the instrument still malfunctions, 
disconnect the batteries for a few seconds. 

Safety 

 WARNING! Failure  to comply  with  safety  warnings 

can cause serious injury or death 

CAUTION!:  Failure  to  comply  with  safety  cautions  can 
result in damage to equipment or property 

This  equipment  shall  be  used  only  by  qualified  and 
trained  personnel,  and  only  after  fully  reading  this 
Operation Manual. 

 

 WARNING! Direct connection to live conductors is 

POTENTIALLY  LETHAL.  Direct  connections  to  live 
conductors  should  be  attempted  by  fully  qualified 
personnel  only  using  the  relevant  products  that  allow 
connections to energized lines. 

 WARNING! The transmitter is capable of outputting 

potentially  lethal  voltages.  Take  care  when  applying 
signals to any pipe or cable and be sure to notify other 
technicians who may be working on the line. 

 WARNING! Reduce audio level before using 

headphones to avoid damaging your hearing. 

 WARNING! This equipment is NOT approved for use 

in areas where hazardous gases may be present. 

 WARNING! Before removing the transmitter battery 

pack, switch off the unit and disconnect all cables  

  WARNING!  The  RD8100  locator  will  detect  most 

buried conductors but there are some objects, including 
live objects, which do not radiate any detectable signal. 
The  RD8100,  or  any  other  electromagnetic  locator, 
cannot  detect  these  objects  so  proceed  with  caution. 
There are also some live cables which the RD8100 will 
not be able to detect in Power mode. The RD8100 does 
not  indicate  whether  a  signal  is  from  a  single  cable  or 
from several in close proximity. 

CAUTION: The battery cover, the accessory cover and 
the headphone cover protect the 

locator’s sockets from 

debris  and  water  ingress.  If  they  get  damaged  or  lost, 
contact 

Radiodetection 

or 

your 

local 

service 

representative for a replacement one. 

Batteries 

 WARNING! Batteries can get hot after prolonged use 

at  full  output  power.  Take  care  while  replacing  or 
handling batteries. 

  WARNING!  Do  not  tamper  with,  or  attempt  to 

disassemble the battery packs. 

CAUTION: If battery failure is suspected return the entire 
unit to an authorized repair center for investigation and 
repair. Local, national or IATA transport regulations may 
restrict the shipment of faulty batteries. Check with your 
courier for restrictions and best practice guidelines. Your 
local Radiodetection representative will be able to direct 
you to our authorized repair centers. 

  WARNING:  Exposing  the  battery  to  a  high 

temperature  above  60°C  (140°F)  may  activate  safety 
systems and cause a permanent battery failure. 

Содержание RD8100

Страница 1: ...RD8100 Precision Multifunction Cable Pipe Locator Operation manual 90 RD8100 OPMAN ENG 03...

Страница 2: ...3 Current readings 26 Section 7 Locating techniques 28 7 1 Identifying target utilities 28 7 2 Signal ground connection 29 7 3 Double ended connections 29 Section 8 Using accessories 30 8 1 About acc...

Страница 3: ...to live conductors is POTENTIALLY LETHAL Direct connections to live conductors should be attempted by fully qualified personnel only using the relevant products that allow connections to energized li...

Страница 4: ...e equipment must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital dev...

Страница 5: ...Manual outline Section 1 includes an overview of safety procedures and notices Review them before moving on to Section 2 and the rest of this manual Section 3 provides an overview of the RD8100 system...

Страница 6: ...only the minimum level necessary to take your measurements Excessive exposure to loud sounds can cause hearing damage Do not attempt to open or dismantle any part of this equipment unless directed spe...

Страница 7: ...15 Radiodetection Ltd 6 Figure 3 1 RD8100 Locator GPS active seeking satellite lock GPS satellite lock acquired 3 5 satellites fixed 6 8 satellites fixed 9 11 satellites fixed 12 or more satellites fi...

Страница 8: ...con Displays the volume level 22 Current Direction arrows 23 Radio Mode Indicates when Radio Mode is active 24 Power Mode Indicates when Power Mode is active 25 Accessory indicator Indicates when an a...

Страница 9: ...2015 Radiodetection Ltd 8 Figure 3 2 Tx Transmitter...

Страница 10: ...mitter is in Induction Mode 18 A Frame Tx 5 B or Tx 10 B only Indicates when the transmitter is in Fault Find Mode 19 CD Mode indicator Tx 10 B only Indicates that the transmitter is in Current Direct...

Страница 11: ...a modes with the exception of Peak FREQ Enable or disable individual frequencies ALERT Enable or disable StrikeAlert BATT Set battery type Alkaline NiMH or Li Ion ARROW Select NULL or proportional Gui...

Страница 12: ...rtment Insert 2 good quality D cell batteries Note the polarity of the cells when inserting them in the battery tray Figure 4 2 Inserting locator batteries On the transmitter To fit the D cell batteri...

Страница 13: ...battery pack If using the Li ion battery pack plug the lead into the battery connector fig 4 7 Figure 4 7 Connecting the Li Ion lead NOTE Fully charge your lithium ion battery pack before its first us...

Страница 14: ...ut connector on the front of the battery pack Transmitter Li ion battery pack To recharge the battery pack remove the pack from the transmitter and connect the transmitter battery charger Figure 4 13...

Страница 15: ...Select standby maximum standard power Table 4 2 Transmitter key actions NOTE to scroll through frequencies from high to low hold while pressing the button applies to both locators and transmitters 4...

Страница 16: ...menu using the or arrows 3 Press the key on the locator or the key on the transmitter to enter the BATT menu 4 Scroll through the battery options using the the or keys 5 Press the key to accept your s...

Страница 17: ...a flashing mode icon Both the depth and current measurements will be disabled in the event of an overload 4 7 TruDepth measurement All RD81 00 locators use TruDepth to measure depth automatically when...

Страница 18: ...neral purpose locate frequency for the intended locate task by measuring the impedance of the target cable or pipe SideStepauto helps to improve locate accuracy by determining the best signal SideStep...

Страница 19: ...rity It is also possible to measure potential voltage that may be present on utilities to warn of potentially dangerous or harmful voltages present In measure mode the measurement is derived from an A...

Страница 20: ...paired device OFF Select this to switch off the internal GPS module and save battery SBAS Select this to switch ON or OFF SBAS Satellite Based Augmentation System SBAS can improve GPS accuracy particu...

Страница 21: ...ON When using custom frequencies in the range of 692Hz to 704Hz or 981Hz to 993Hz the locator audio may interfere with the locator and must be turned off NOTE Some frequencies e g 440Hz may be reserve...

Страница 22: ...cating Buried Pipes and Cables which is available as a free download from www radiodetection com To select a frequency on the locator 1 Press the key to cycle through available frequencies 2 Alternati...

Страница 23: ...response is at its maximum level where the Null point is located then there is no or very limited distortion present In Peak mode the following indicators are displayed by the LCD Right and left arrow...

Страница 24: ...tion of a target line after it has been traced and its position is approximately known Start with medium output power from the transmitter medium frequency on the transmitter and locator and Peak or P...

Страница 25: ...ductive search procedure is a more certain technique for locating unknown lines This type of search requires a transmitter and locator and two people This type of search is referred to as a two person...

Страница 26: ...to note that the RD8100 locator will only display depth and current in applicable modes when the locator is correctly orientated above the target line cable or sonde To ensure the locator is correctly...

Страница 27: ...er 1 Switch the locator on 2 Select the same frequency as is selected on the transmitter but make sure that this frequency is in the sonde mode 3 Move the locator from left to right and when the bargr...

Страница 28: ...ducts that allow connections to energized lines Signal current measurements Pinpoint the line and confirm the accuracy of the Peak pinpoint with null arrows Check the locator is directly over the line...

Страница 29: ...r to marking the wrong line A certain degree of coupling is unavoidable in many situations but there are ways in which a careful user can reduce coupling and increase location reliability Avoid applyi...

Страница 30: ...the best possible grounding for the transmitter This provides the lowest resistance ground path and the best output signal If it is not possible to use the ground stake the following are examples of...

Страница 31: ...y Exercise caution 8 3 Locator clamps A locator clamp is used to positively locate and identify a cable when several cables are running close together A target cable can be identified in a chamber on...

Страница 32: ...effective method of applying the signal than Direct Connection The target line will carry the strongest signal The other lines will carry the weaker return signal If the system comprises only two cond...

Страница 33: ...ewer pipes Consult the precision locate accessory range brochure or web page on www radiodetection com for a full list of all available sondes and their technical specifications Check that the sonde h...

Страница 34: ...npoint and mark the position Repeat this pinpoint procedure at similar intervals along the line of the drain or duct until the survey is completed Checking sonde depth The RD8100 locator will automati...

Страница 35: ...er for identifying inaccessible small cables Miniature hi gain stethoscope The miniature stethoscope is similar to the small stethoscope but has no handle or facility for extension rods The miniature...

Страница 36: ...is prudent for the pair to practice working together on dry land before attempting to locate underwater Using the antenna the diver should locate and trace a known line blindfolded receiving directio...

Страница 37: ...d the connection is clean and that a positive connection is achieved 3 Extend the black connection lead as far away as possible at 90 to the probable route of the target cable and clip the connector t...

Страница 38: ...hrough all available antenna modes until the locator goes back to fault find mode Note While the A Frame is connected to the locator depth and current measurements will not be available If depth or cu...

Страница 39: ...with a normal clamp or induction These can however be applied with a transmitter CD clamp Using Current Direction CD to aid line identification The RD8100 PDL PTL locators and Tx 10 and Tx 10B transmi...

Страница 40: ...the example shown in the illustration by returning to C which is the last point at which a CD reading was achieved and performing a CD reset the response at C will be equivalent to that of A In most...

Страница 41: ...lication See chapter 12 4 for instructions on how to enable the Bluetooth transmission to a paired device If your PDA is out of reach or if its Bluetooth features are disabled the locator will display...

Страница 42: ...ager is compatible with PCs running Microsoft Windows XP 7 8 and 8 1 To send stored data to your paired PDA 1 Ensure your paired PDA is switched on and running the SurveyCERT app 2 Press the key to en...

Страница 43: ...on 5 Press the key to switch Bluetooth off and return to the previous menu 12 3 Pairing to a transmitter To pair to a transmitter you require a Bluetooth enabled model such as the Tx 5B or Tx 10B Befo...

Страница 44: ...rt 12 5 Bluetooth Protocol RD8100 locators can transmit survey measurements to a paired PDA device running a compatible program To set the locator to work with Radiodetection s SurveyCERT application...

Страница 45: ...RD8100 wireless Bluetooth technology features Radiodetection recommends resetting the connection and then pairing your device again To reset the wireless connections 6 Press the key to enter the menu...

Страница 46: ...ency is displayed on screen 2 iLOC commands are sent using the key press it to send the new frequency to the transmitter 3 The locator s LCD will display SEND momentarily and then OK if the transfer i...

Страница 47: ...or there may be an error in the connection Move closer to the transmitter and retry the procedure If the connection continues to fail return to the transmitter and reset the connection using the proc...

Страница 48: ...adiodetection or a Radiodetection approved repair center Regularly check your locator for correct operation using eCert see section 14 6 and the on board Self Test NOTE Service by non approved service...

Страница 49: ...e 10 Indicate if you do not wish to receive e mail or other marketing material with new product information or special offers and promotions related to its product range 14 5 Upgrading software From t...

Страница 50: ...ame Bag 10 RX AFRAME BAG A Frame replacement lead 10 RX AFRAME LEAD 2 50mm Locator signal clamp 10 RX CLAMP 50 4 100mm Locator signal clamp 10 RX CLAMP 100 5 130mm Locator signal clamp 10 RX CLAMP 130...

Страница 51: ...SONDE STD 33 Standard Sonde 8kHz depth up to 5m 10 SONDE STD 8 Standard Sonde 512Hz depth up to 5m 10 SONDE STD 512 Sewer Sonde 33kHz depth up to 8m 10 SONDE SEWER 33 External Shell for heavy duty App...

Страница 52: ...10 RX MBATPACK LION K XX Li Ion rechargeable battery mains kit includes mains charger Replace XX with US UK EU or CN Li Ion automotive charger 10 RX ACHARGER LION Li Ion mains charger 10 RX MCHARGER...

Страница 53: ...d case 10 RD7K8KCASE USA Miscellaneous Safety equipment Warning triangle 10 WARNING TRIANGLE Calibration Certificates Remote Calibration and PC Software Locator Calibration Certificate per unit reques...

Страница 54: ...USA 39 740 Garand Lane Unit B Palm Desert CA 92211 USA Tel 1 800 688 8094 Tel 1 760 343 7350 pearpoint sales us spx com www pearpoint com Radiodetection Canada 344 Edgeley Boulevard Unit 34 Concord On...