background image

PG

 4

PG

 4

PG

 5

HOLIDAY PROGRAM - 

This is a single program that repeats day after day until you turn it off. It 

supersedes the weekly program. To modify it touch PROGRAM on the MANUAL screen. It uses the 

Calendar method for programming (see pg7 ).

VACATION - 

This function will hold a pre-set temperature until you turn it off. The preset is saved for 

next time.

FRESH AIR - 

If you have a fresh air baffle connected to the EX terminal, the CT80 will use this 

outside air source as the 1st stage of heating or cooling. Useful in desert climates where outside air 

temp can change very quickly or just to freshen indoor air quality.

EMER HEAT - 

This is available if you have a HEAT PUMP with auxiliary heat. When you select this 

your HEAT PUMP is disabled and auxiliary heat is your sole source of heat.  This manual override 

setting stays  active until you turn it off. (This command is not displayed if you do not have a heat 

pump).  Remember auxiliary heat is more expensive than the heat pump.

Run the pre-set program

The CT80 comes pre-programmed with an EPA approved program. This program was recommended 

by the EPA for energy efficiency. We strongly recommend that you run this program for one week, 

and see if it works for you. If it does not fit your needs you can always input a custom program. 
• To run the EPA program, press  

 and select HEAT or COOL with the mode selection. Set the time 

and day and Press HOME. The unit is now running the EPA program.

 

Содержание CT80

Страница 1: ...screen ENGLISH Statement of use 100 Compatible with all popular residential HVAC systems 24VAC single two three stage conventional heating systems gas oil electric heat pumps single and two stage comp...

Страница 2: ...rn you to this screen To set a Mode Press the Power button on the control bar Touch the desired mode from the choices displayed at the bottom COOL HEAT AUTO or OFF Touch HOME when done Set the time by...

Страница 3: ...r device Network control Use this to configure network connections Information access Use this to access info screens from network connections Set o F o C Touch this to set temperature display Lock Co...

Страница 4: ...et temperature you set indefinitely until you turn it off Take care using the HOLD function To set a hold touch HOLD to initiate a hold temperature You can use the buttons to select your hold temperat...

Страница 5: ...R HEAT This is available if you have a HEAT PUMP with auxiliary heat When you select this your HEAT PUMP is disabled and auxiliary heat is your sole source of heat This manual override setting stays a...

Страница 6: ...then touch PROGRAM in the upper left of the screen The PROGRAM BY INTERVIEW screen will come up 3 Read each question and fill in your answers by touching the answer in brackets 78o to highlight and u...

Страница 7: ...r to make changes after programming in Interview mode To create a whole new program With the CT80 in HEAT or COOL mode 1 Press MENU and then touch PROGRAM in the upper left of the screen 2 Touch the C...

Страница 8: ...ram The CT80 can hold 2 complete weekly programs in memory Prog A is the default The interview program is stored in prog A To switch to the B program touch the A B icon COMFORT The Comfort Settings on...

Страница 9: ...To set adjust 2nd STAGE ON AT 1 Press Menu and then touch COMFORT 2 Touch and highlight the user setting next to 2nd STAGE ON AUX ON AT 3 Use the buttons to raise or lower the setting from 2 0 to 6 0...

Страница 10: ...CT80 s humidistat can also control the Air Conditioner for de humidifying To set a maximum humidity level using the air conditioner 1 Press MENU then touch the HUMIDITY then view DE HUMID by A C 2 Tou...

Страница 11: ...s such as air filters humidifier pads and UV bulbs should be checked and or changed HUM PAD Run time of humidifier AIR FILTER Real time of HEAT COOL UV BULB Real time To set adjust CHECK CONSUMABLES A...

Страница 12: ...eature by touching the function PARTIAL Limits the user to temporary override the CT80 target temp The override is limited to 9o F 5o C To change this range touch RANGE and using the buttons to adjust...

Страница 13: ...screen will also automatically increase or decrease for each 1 F adjustment The large display will show the modified temperature reading that will be displayed on the HOME screen in normal operation 4...

Страница 14: ...ed at the top center of the HOME screen AUTO The fan control is normally set to AUTO mode meaning that the fan operates automatically CIRC The CIRC function allows your fan to automatically circulate...

Страница 15: ...and COOL temps and then select the AUTO mode The CT80 will switch from HEAT to COOL as needed OFF This takes your HVAC system off line and it will not control HVAC functions In this mode your house ma...

Страница 16: ...CT80 first 3 Power up CT80 NOTE DO NOT HOT SWAP RTM 1 USNAP modules this can damage the thermostat or radio modules To MATE to a network 1 Select MENU then NETWORK 2 Make sure the network is ON 3 Sele...

Страница 17: ...r enabled power meter Home automation systems can also utilize the INFORMATION function for interactive and informative messages They can display text and alpha numeric information on energy use HVAC...

Страница 18: ...ms may be available to connect your thermostat to power grid status information This can make it easy for you to moderate your energy use at peak hours and use power when it is less expensive The RTM...

Страница 19: ...PG 19...