Radio Systems, Inc.
•
601 Heron Drive
•
Logan Twp., New Jersey 08085
(856) 467-8000
•
Fax (856) 467-3044
•
www.studiohub.com
3
St Model HUB16-DC and HUB8-DC
Engineered for St and High-Speed Ethernet Connectivity
General
Each of 16 (or 8 if ordered in the
Ω
Hub model) Hub
channels consists of an RJ-45 input connector in parallel with
an output RJ-45 connector and a 110-style punch connector.
Each channel carries a stereo balanced audio pair, or
balanced digital audio signal, and an op/- 15 DC
voltage. Equipment cabling may also be punched down to
the inline 110 connector.
DC Power
If using any St "DC-Link" accessories, plug a
Stu/- 15 volt power supply into the power supply
connector. Both Hub LED s will illuminate. Insert both
power jumpers and the DC ground jumper on only the
circuits that utilize a powered accessory (e.g. MatchJack, mic
preamp, etc.).
Grounding Information
Cable and connector shields are contiguous from each
individual hub channel (input to output) but are normally
isolated from other channels.
To use the hub as a common ground point, insert the jumper
below each left-hand RJ-45 that you want common to the
chassis ground. If you have a St 15V power supply
connected to the hub, and JU-33 is jumpered, chassis ground,
electrical ground, and shield are common.
For Assys:
HUB16-DC
HUB8-DC
Rev: 01/05
Note:
All 3 of these
jumpers must be inserted
for any channel that is
powering a remote DC-
Link device (e.g.
St MatchJack
or Pre-Amp)
Name
HUB16 / HUB8
Mount
Hub (3 r.u.)
Channels
16 / 8
CAT-5 Pairs
4 (all)
Power Link
yes
Connectors
2 RJ-45 & 110
Versions
Full Hub/Half Hub/Board Only
Product Key
Insert jumper under any
right-hand jack to
connect that channel s
shield to the common
shield bus
Insert jumper to connect
to the power supply
shield
Insert jumper under any
left-hand jack to connect
that channel s shield to
the common chassis
ground
Install both DC jumpers
to activate St
DC-Link connection to
p/-15V DC to
any powered accessory
This jumper connects the
channel to the common
power ground bus when
installed. Required for
DC-Link operation.
Note: This jumper must
be removed for KVM
extender links and other
data devices that use
CAT-5 wire #4 (blu/wht)
LED s indicate presence of
+/- 15V DC
10 pin 110-style connector
provides access to all 4 CAT-5
pairs and cable shield
+/-15V external power
supply main and loop-
thru jumpers
Shield
x 16
or 8
J2
Power
Supply
Ground
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
J4
RJ-45-2
JU34
Hub
Chassis
Ground
JU4
JU3
Power
Supply
Shield
JU33
110 Connector
J3
JU1
15v+
1/2 Amp
auto-reset fuse
R1
JU2
15v-
1/2 Amp
auto-reset fuse
R2
RJ-45-1
Blu/Wht G
Wht/Org L+
Org/Wht L-
Wht/Grn R+
Grn/Wht R-
Wht/Brn - 15V
Brn/Wht + 15V
Slt/Wht Shd
Wht/Slt Shd
Wht/Blu n/c
Model HUB16 pictured
Also available as
Ω
hub 8 channel - model Hub8
Содержание DA12-DC
Страница 1: ...Technical Manual for Hubs Updated 09 07 ...