Three-phase industrial circuits are extremely
powerful. You can be burned severely and
even killed if you create an accidental short
in these panels.

Before measuring voltages, put on
protective clothing – a face shield and
fireproof gloves and upper body protection is
required. If you do not have this protection,
DO NOT MEASURE THESE CIRCUITS.

Most 3-phase power circuits are rated by
their line-to-line voltage. This voltage is
higher than the line (or phase) to ground
voltage. To determine if a line-to-line 3-
phase voltage exceeds the rating of this
meter, multiply the rated line-to-ground
voltage by 1.732 (the square root of 3). For
example, if the rated line-to-ground voltage
is 400 volts, the line-to-line voltage is 400

×

1.732 = 692.8 V AC.

o

M

EASURING

 DC/AC C

URRENT

To measure AC or DC current, you must
break the circuit and connect the test leads
to two circuit connection points. The
connection must be in series with the circuit
under test.

1. Disconnect power from the circuit you

will test and discharge all capacitors.

2. Rotate the function dial to

.

3. Repeatedly press

SELECT

to select DC

or AC.

appears for AC current

measurement.

4. Connect the black test lead to one of

the two connection points on the
broken circuit.

o

 WARNING 

o

 

This voltage (692.8V
AC) exceeds the
meter’s rating.
Therefore, you should
not connect the meter
to this circuit or to any
equipment connected
to the circuit. Doing
so could present a
dangerous shock
hazard to you, and
could also damage
the meter.

When the meter is set
to its current
measurement
function, do not apply
voltage directly
across terminals. You
must connect the
meter in series with
the circuit.

 CAUTION 

When the meter is set
to its current measure-
ment function, never
connect the test leads
across a voltage
source. Doing so can
damage the meter or
the circuit under test.
The maximum input
limit for AC/DC current
measurement is 10A.

If you do not know the
amount of current in
the circuit you are
measuring, always
connect the red test
lead to

+ 10A MAX

.

mA/A

Содержание 22-813

Страница 1: ...et the range when measuring values you know are within a certain range Latest IC and Display Technology ensures reliability accuracy stability and ease of operation Bar Graph Display makes nulls peaks...

Страница 2: ...rated for installation category II max 3600 VA Never apply voltages to the meter that exceed the limits given in the specifications Never apply more than 600V DC or AC between the input jacks and grou...

Страница 3: ...ate that this product has been evaluated by Underwriters Laboratories for the accuracy of its readings Your meter requires three AAA batteries not supplied Your meter also has these additional feature...

Страница 4: ...Laboratories The maximum current that this meter can measure at this jack is 400 mA DC and AC Caution Be extra careful when making high voltage measurements DO NOT TOUCH TERMINALS OR PROBE ENDS Cauti...

Страница 5: ...r You can order replacement leads from your local RadioShack store o oWARNING o To avoid electrical shock disconnect both of the test leads from any equipment before you install or replace the meter s...

Страница 6: ...wn any button while turning on the meter The meter turns on and all segments on the display appear Release the button you are holding down to turn off the test CAUTION Be sure to select the correct fu...

Страница 7: ...the function dial to then press SELECT twice appears Measurement Function select using SELECT button 1 Measures DC voltage 2 Measures AC voltage 1 Measures amperage DC 40 400 mA AC 40 400 mA 2 Measur...

Страница 8: ...ges The unit of measure that appears on the display shows the range that the meter is currently set to For example mV appears in the 400 mV range Also note the position of the decimal For example if 0...

Страница 9: ...d ddd V 40 V dd dd V 400 V ddd d V 600 V ddd V 40 mA dd dd mA 400 mA ddd d mA 4 A d ddd A 10 A dd dd A 400 ddd d 4 k d ddd k 40 k dd dd k 400 k ddd d k 4 M d ddd M 40 M dd dd M NOTE V mA is fuse prot...

Страница 10: ...press any button or select another function o USING POWER LOCK Follow these steps to set the meter so that it does not turn off automatically 1 Rotate the function dial to OFF to turn off the meter 2...

Страница 11: ...e measuring C D AA and AAA batteries One segment of the bar graph appears for each 0 6 volts if you are measuring 9 volt batteries If all segments of the bar graph appear the battery being measured is...

Страница 12: ...pens touch the test leads together or change the meter s setting to clear it oWARNING o When measuring high voltages always clamp the meter s black test lead to ground or neutral first then the red te...

Страница 13: ...AC voltages If you want to measure 3 phase line to line voltage please note the following Because of the dangers inherent in measuring three phase circuits we strongly recommend you do not use this m...

Страница 14: ...nection must be in series with the circuit under test o 1 Disconnect power from the circuit you will test and discharge all capacitors 2 Rotate the function dial to 3 Repeatedly press SELECT to select...

Страница 15: ...ther lead of the component you want to measure or remove one of the leads of the component you want to measure from its circuit and touch the test leads across the component If the meter is set to aut...

Страница 16: ...s and the buzzer sounds if the circuit resistance is less than about 50 ohms meaning the circuit has low ohmage or is shorted Open appears and the meter s buzzer does not sound if the circuit resistan...

Страница 17: ...t you want to measure from its circuit and touch the test leads across the component Then note the first reading 6 Reverse the test leads and note the second reading If one reading shows a value and t...

Страница 18: ...ter shows a higher voltage using the red test lead is the anode side CHECKING BATTERIES The meter can accurately check batteries under designated load conditions You can use the meter to test 1 5V C D...

Страница 19: ...volts Good and the number of volts appear Battery is good 9 volts Good and the number of volts appear Battery is full NOTE When testing 1 5V C D AA and AAA size batteries if the battery s voltage is b...

Страница 20: ...lly wipe it with a cloth slightly dampened with water Do not use harsh chemicals cleaning solvents or strong detergents to clean the meter o REPLACING THE FUSE If the meter does not operate you might...

Страница 21: ...insert the fuse into the fuse holder 5 Replace the back cover of the meter then secure it with the screws SPECIFICATIONS Accuracies at 23 C 5 C 75 RH DC VOLTS Maximum Measurement 600V 400mV 0 5 of Rea...

Страница 22: ...in Last Digit 400k 4 0M 1 2 of Reading 4 in Last Digit 40M 2 0 of Reading 4 in Last Digit BATTERY TEST 1 5V C D AA 150mA 10 load current 5 0 of Reading 4 in Last Digit 1 5V AAA 50mA 10 load current 5...

Страница 23: ...ource 3 AAA batteries Operating Temperature 41 F to 104 F 5 C to 40 C Storage Temperature 4 F to 140 F 20 C to 60 C Humidity Maximum Relative Humidity 80 for temperatures up to 87 8 F 31 C decreasing...

Страница 24: ...u In the event of a product defect during the warranty period take the product and the Ra dioShack sales receipt as proof of purchase date to any RadioShack store RadioShack will at its option unless...

Отзывы: