background image

18

19

Scanning and Monitoring

Press 

SCAN/MAN 

until 

SCAN

 appears to continuously 

scan through all channels with stored frequencies. If the 

scanner finds an active frequency, it pauses until the 

transmission ends.

Press 

 or 

 to change the scanning direction.

To monitor a channel, press 

SCAN/MAN

 so that 

MAN

 

appears.

The scanner does not scan channels in banks that are 

turned off. To turn a channel-storage bank on or off, 
press the bank’s number key (

1–0,

 using 

0

 for bank 10) 

during scanning. The channel-storage banks that are ON 
have a bar underneath them. 

•   You cannot turn off all banks; there must be at least one 

active bank.

•   You can manually select any channel in a bank, even if 

the bank is turned off.

Setting Delay

To avoid missing a reply in conversations, a two-second 

delay is automatically set for each channel. The scanner 
stops for two seconds after a transmission ends before 
it resumes scanning or searching. 

DLY

 appears on the 

display when the delay function is active.

To turn delay on:

•   If the scanner is scanning and stops on an active 

channel, quickly press 

•/DELAY 

before it resumes.

•   If the desired channel is not selected, manually select 

the channel, then press 

•/DELAY

.

•   If the scanner is searching, press 

•/DELAY

DLY

 

appears and the scanner adds a two-second delay to 
every transmission it stops on in that bank.

To turn delay off:

Press 

•/DELAY 

while the scanner is monitoring a channel 

or frequency. 

DLY

 disappears.

Using the Priority Channel

The priority feature sets the scanner to check one 

specific channel every two seconds while scanning. You 

can only program one frequency into the priority channel. 

1.

   Press 

PGM

.

2.

 Press 

PRI/ALERT.

 

PCH

 and 

000.000

0

 (or the previously 

stored frequency) appear.

3.

   Enter the frequency you 

want stored in the priority 

channel, then press 

ENT

4.

  To turn on the priority 

feature, press 

 

PRI/ALERT 

during scanning 

or searching. 

PRI

 appears. 

The scanner checks the priority channel every two 
seconds and stays on the channel if there is activity. 

  To turn off the priority feature, press 

PRI/ALERT.

 

PRI

 disappears.

Signal Stalker II

Signal Stalker II allows you to sweep a range of 

frequencies to detect, monitor and store frequencies for 

nearby radio transmissions. 

The Signal Stalker II feature is more sensitive than 
portable frequency counters and detects transmissions 
at greater distances.

The Signal Stalker II can be set to watch for activity on 

all bands, or on Police/Fire, Aircraft, or Ham frequencies 

exclusively. 

When the scanner is in manual, scan or tune mode, press      

 to watch for activity on all bands. 

To watch for activity on Police/Fire, Aircraft, or Ham 
frequencies exclusively, press the button for the desired 

service bank and then press 

 . 

NOTE:

 Priority mode is not available while using the 

Signal Stalker II.

1

4

3

2

Содержание 2000649 / PRO-649

Страница 1: ...anish at www radioshack com Esta gu a del usuario est disponible en espa ol en www radioshack com handheld Radio Scanner Thank you for purchasing your Handheld Radio Scanner from RadioShack Please rea...

Страница 2: ...re departments ambulance services government agencies private companies amateur radio services military operations pager services and wireline telephone and telegraph service providers It is legal to...

Страница 3: ...you can hear replies on the same channel Priority Channel Lets you set the scanner to check one channel every 2 seconds so that you do not miss transmissions on that channel Data Cloning Lets you tra...

Страница 4: ...eath Callthepowercompanytoremovethe antenna DONOTattempttodosoyourself ConnectingaSpeakerorHeadphones You can plug an amplified speaker or headphones not supplied with inch 3 5 mm mini plug into the H...

Страница 5: ...ly Do not burn or bury them Do not mix old and new batteries different types of batteries alkaline or rechargeable or rechargeable batteries of different capacities If you do not plan to use the scann...

Страница 6: ...mbers or select banks 0 selects bank 10 The number range above the keys 1 20 21 40 41 60 etc indicates the channels stored in that bank DELAY Input a decimal point or set a channel delay ENT Enter Com...

Страница 7: ...N Manual mode PGM Program mode PRI Priority feature is active DLY Two second delay is active Display Messages ALL CH L out All channels locked out during scan or marine band search b X Ch FULL All dis...

Страница 8: ...ENT start again from Step 2 If the frequency is already stored in another channel the scanner beeps three times and displays dUPL duplicate and the lowest channel number where the frequency is already...

Страница 9: ...empty channel of the selected bank If the scanner displays dUPL the frequency is already stored in another channel Press ENT to continue Press TUNE CLEAR to cancel If there are no empty channels in th...

Страница 10: ...transmission it stops on in that bank To turn delay off Press DELAY while the scanner is monitoring a channel or frequency DLY disappears Using the Priority Channel The priority feature sets the scan...

Страница 11: ...for about two seconds during a Service Bank search 2 Press or repeatedly to scroll through the list of locked out frequencies L r and L 0 appear in the display 3 Press L O L O RVW to remove the lock...

Страница 12: ...ent code A current list of FIPS codes is located at www NWS NOAA gov NWR SAME Standby Mode In SAME Standby mode your scanner monitors weather channels for SAME alerts for up to seven areas you specify...

Страница 13: ...immediately Use and store the scanner only in normal temperature environments Handle the scanner carefully do not drop it Keep the scanner away from dust and dirt and wipe it with a damp cloth occasio...

Страница 14: ...7125 147 467 7625 148 467 8125 149 467 8500 150 467 8750 151 467 9000 152 469 5000 153 469 5500 Channel Frequency MHz Bank 1 1 40 5000 2 52 5250 3 121 5000 4 122 0000 5 122 2000 6 122 7000 7 122 7500...

Страница 15: ...0 148 000 5 Group 4 420 000 450 000 12 5 Weather Channel Frequency MHz 1 162 400 2 162 425 3 162 450 4 162 475 5 162 500 6 162 525 7 162 550 Marine Channel Frequency MHz 01 156 0500 05 156 2500 06 156...

Страница 16: ...ment without notice Actual product may vary from the images found in this document FCC Notice This equipment has been tested and found to comply with the limits for a scanning receiver pursuant to Par...

Страница 17: ...ack Replaced parts and products are warranted for the remainder of the original warranty period You will be charged for replace ment of the product made after the expiration of the warranty period RAD...

Страница 18: ...2014 RadioShack Corporation All rights reserved RadioShack is a registered trademark used by RadioShack Corporation 2000649 06A14 Printed in Korea...

Отзывы: