NOTICE: Always adhere to the nominal or peak power of pellets combustion, that is
when pellets are burning on top of the burner. In this case, decreasing thermal power is
done by decreasing the set temperature of water in the boiler or set temperature of the
room thermostat.
Picture 25. The representation of the perfect combustion of pellets
Warning: It is mandatory to analyze flue gases upon installing the boiler.
Measure percentage of oxygen (O2).
7.3 A short guide to using automation
7.3.1. Filling the firebox with pellets, preparing for ignition and starting the pellet fire
The procedure is shown in the picture below:
Picture 26. Starting the boiler