Control buttons
In the bottom right corner of each command button, there is a number.
-
TURN ON-OFF P CONTROL BUTTON 4:
Initiates the system on pellets as fuel when held
for 5 seconds. Also, shuts down the system in which pellets are used as fuel by holding this key for 5
seconds. By pressing in the Menu, the value of parameters is increased.
-
TURN ON-OFF WOOD/+ CONTROL BUTTON 3:
Initiates the system on solid fuel when held for 5
seconds. Also, shuts down the solid fuel system by holding this key for 5 seconds. By pressing in the Menu,
the value of parameters is decreased
.
-
SET/Screw CONTROL BUTTON 2:
While held in the mode OFF, manual loading of pellets into the
furnace starts. During this process, the LOAD message will appear on the display. Manual loading of the
furnace with pellets stops upon release of this key.
Pressing in the
MENU
the display of the parameter code changes to the value and saving new
settings is allowed.
-
ESC/Menu CONTROL BUTTON 1:
This key enters/exits the MENU. If you are changing settings and
press this button, changes in settings will not be saved.
NOTICE:
In the OFF mode or SHUT DOWN mode you can reset the Alarm display by pressing keys + or -
, but if the cause of the alarm is still present the alarm will start again
.
Light diodes
1.
Light diode Screw: ON: ON
when the auxiliary combustion fan works.
2.
Light diode Fan: ON
when the auxiliary combustion fan works.
3.
Light diode Pump P: ON:
when the pump works. BLINKS when the pump is shut down by the
room thermostat.
4.
Light diode Boiler: ON
when the water temperature in the boiler goes below value T-
BOILER[A03] – ModulationDelta1 [A05]. BLINKS when the water temperature in the boiler is
above the set value. OFF when the water temperature in the boiler is above temperature T-BOILER
[A03]
.
5.
Light diode Exhaust: ON
when the exhaust temperature is above T-EXHAUST-ON[F18].
BLINKS during the pre-shutdown mode.
6.
Light diode Pellets: ON
when the boiler works in pellets mode. BLINKS during the pre-shutdown
mode (pre-shutdown time[t06]).
7.
Light diode Initiation heater: ON:
when the initiation heater works
.
8.
Light diode Wood: ON
when the boiler works in solid fuel mode
.
9.
Light diode Recipe 1: ON
when Recipe 1 is selected.
10.
Light diode Recipe 2: ON
when Recipe 2 is selected.
11.
Light diode Chrono: ON
when the Chrono output is closed.
Display