Radijator Inženjering d.o.o, 36000 Kraljevo, Živojina Lazića - Solunca br.6, Srbija
tel. +381 36 399 140, fax. +381 36 399 150, http://www.radijator.rs
e-mail: [email protected]
53
5.
Technical data table
BOILER TYPE
PK 18
CE mark
CE
Boiler class according to EN 303-5:2012
V
Working pressure
bar
3
Test pressure
bar
4.5
Firebox volume
L
83
Volume of water in the boiler
L
100
Weight
kg
425
Chimney cross-section
mm
160
Required chimney draft
mbar/Pa
0.12/12
Boiler temperature (min/max)
°C
60-90
Min. temperature of the return line
°C
60
Efficiency rate
%
90.3
Nominal power
(kW)
18.07
CO emission with rated heating power (10%O
2
) *
(mg/m³)
126.57
NO
x
emission with rated heating power (10%O
2
) *
(mg/m³)
175.75
OGC emission with rated heating power (10%O
2
) *
(mg/m³)
5.02
Dust with rated heating power (10%O
2
) *
(mg/m³)
18.44
Dimensions
A
410
A1
504
B
990
B1
1283
C
1124
D
150
E
132
F
419
G
1113
H
1120
I
1409
Hot boiler water connections
D1
1"
Cold boiler water connections
D2
1"
Connections for boiler filling and emptying
D3
1/2"
Connections for air bleeding valve and pressure safety valve
D4
1/2"
Connection for flow out valve for thermal safety VTO
D5
3/4"
Connection for probe for thermal valve
D6
1/2"