Delivery Item
No of units
Boiler
1
Assembly set
1
Instruction for use
1
2.4 Minimum separation distance and flammability of building
materials
Minimum separation distance from inflammable materials may differ from country to country.
Please adhere to the regulations on electrical installations and prescribed minimum distances
in your country. The following table shows the classification of flammability of building
materials as per DIN 4102.
Flammability of building materials
A
A1
A2
Non-combustible
Non-combustible
Asbestos, stone, ceramic wall tiles, terracotta,
plaster (without organic additives).
Containing minor
quantities of
flammable additives
(organic ingredients)
Gypsum-cardboard plates, base felt plates, glass
fibre, plates of AKUMINE, lycopene
RAYOLITE, LIGNOS, VELOX and
HERACLITE
B Flammable
B1
Not easily flammable
Beech and oak wood, composite wood, felt, plates
of HOBREX, VERSALITE and UMAKART
B2
Flammable
Pine wood, larch and spruce wood,
veneered wood
B3
Easily flammable
Asphalt, cardboard, cellulosic material, tar paper,
particle board, cork, polyurethane, polystyrene,
polyethylene, floor fibres
Table 2. Flammability of building materials per DIN 4102
2.5 Tools, materials and auxiliary aids
For assembly and maintenance of the boiler, standard tools for doing thermo-technical,
plumbing and electrical installations are required.
2.6 Antifreeze protection
If the use of antifreeze additives cannot be avoided, use those additives which are permitted
for heating installations.
2.7 Waste disposal
- Dispose of the packaging in an environmentally friendly manner.
- Dispose of the components which should be replaced in an environmentally friendly
manner.
2.8 Scope of delivery
During delivery of the boiler, adhere to the following:
-
Check whether the packaging is undamaged
During delivery.
-
Check whether the delivery is complete.