13
-
Prior to any works on the heating installations, the power supply should be disconnected.
-
Unskilled and unauthorised attempts of connecting under voltage may cause material
damage on the boiler, which may further lead to dangerous electric shocks.
4.2 Clearance around the boiler to floor, wall and ceiling
DANGER:
Risk of fire due to flammable materials or liquids!
Do not store flammable materials or liquids in the vicinity of the boiler.
Inform the end-user about the regulations in effect relating to minimum
clearance from easily flammable materials (more information in the
table 2)
- Comply with the regulations on electrical installations and minimum clearance that
are in effect in the relevant country.
- Mount the boiler on the wall in such a way that there remains free space, as shown in
picture 6.
Picture 6. Minimum clearance after the assembly of the boiler
a=60mm; b=c=150mm; d=500mm