14
4.3 Removal of the boiler front casing
Prior to any intervention (removal of the casing), disconnect the boiler
from the installation.
Boiler casing may be removed for easy handling and installation. Boiler removal is
performed in the following way:
1. Unscrew the screws at the left, as shown in the picture.
2. Unscrew the screws at the right, as shown in the picture.
3. Remove the boiler front casing by easily pulling it towards yourself.
Picture 7. Opening of the boiler (removing the boiler front casing)
4.4 Assembly of the boiler
The boiler should be assembled on the wall in a vertical position.
The manufacturer is not responsible for damage caused as a result of
unprofessional assembly.
NOTE:
Material damage may be caused by inadequate assembly on the
wall!
Adequate fastener tools should be used.
This section describes the assembly of the boiler on the wall.
NOTE: The boiler must be assembled vertically on the wall.
Assembly procedure:
1.
Mark the position of the hole to be drilled in the wall.
2.
Drill holes as per the measures shown in picture 5.
3.
Drill holes with adequate drill.
4.
Put in the drilled holes the plastic screw anchors, contained in the delivery of
the boiler, or some other screw anchors suitable for non-standard type of wall.
5.
Afterwards, put in the screw anchors the screws delivered in the assembly set
(or some other screws). Screws delivered in the assembly set should stick out
from 5 to 10mm.
6.
Carefully mount the boiler on the wall.
7.