Table 1. Errors in the system and description
Er01
Error activation Safety thermostat 1 High voltage (May activate even when off)
Er03
Extinguishing due to low exhaust temperature
Er04
Extinguishing due to water over-temperature
Er05
Extinguishing due to excessively high exhaust temperature
Er11
Clock error. The error occurs due to problems with the internal clock
Er12
Shut-off due to Ignition Failure
Er15
Extinguishing due to power outage for more than 50 minutes
Er16
RS485 Communication Error
Er18**
Empty Pellet tank
Er23
Boiler Probe or DHW Probe or Delivery Probe or Buffer
Er02*, Er06*, Er07*, Er08*, Er09*, Er10*, Er14*, Er20*, Er25*, Er26*, Er34*, Er35*,
Er67*
*
If these errors occur, call an expert. System wiring should be checked.
**
This error is for accessories not provided for in the standard scope of delivery.
Other Massages:
Sensor
Displaying the status of the Temperature sensors. The message is displayed
during the check-up and indicates that the temperature reading on one or more
probes is equal to the minimum value or the maximum value (depending on the
probe considered). Check that the probes are not open (read the minimum value
of the temperature scale) or short (read the minimum value of the temperature
scale) or short (read the maximum value of the temperature scale).
Service
Message that signals the achievement of scheduled operating hours. Contact the
service centre.
Cleaning
Message that signals the achievement of scheduled operating hours. The stove
or boiler must be cleaned.
Block
Alternative message to the current state, which appears if the system is not
manually switched off during Ignition (after Preload): the system will switch off
when it has reached full capacity operation.
Door
Door open.
Link
error
Lack of communication between keyboard and control board.