Installation Manual 

 

COMBI  -  TA01A011.B1003 

 

 

16

SPARE PARTS SHORT LIST 

 

 

CODE 

DESCRIPTION 

RSF 30 E 

 

 

 

20046LA 

24 PLATE EXCHANGER 17B1902406 

9

 

21032LA 

GAS BURNER 17 R. 1,20 NATURAL GAS 

9

 

21033LA 

GAS BURNER 17 R. 0,75 L.P.G. 

9

 

24040LA 

CIRCULATING PUMP GOLD 50V1 SHUL CLF6 15/6 W/ AIR VENT 

9

 

24041LA 

CIRCULATING PUMP MOTOR SHUL CLF6 15/6 

9

 

31011LA  

D.H.W. – HEATING SENSOR WIRE 

9

 

35007LA 

IGNITION ELECTRODE x ELECTRONIC 

9

 

35009LA IONISATION 

ELECTRODE 

9

 

36066LA 

ELECTRONIC GAS VALVE VK4105 G1112 

9

 

37016LA 

EXHAUST FAN 230V ES 30-108 G 00-0416 

9

 

43157LP 

S CLIPS KIT FOR MULTIPLEX GROUP 

9

 

58009LP 

MAIN HEAT EXCHANGER mod. 30.000 kCal/h 

9

 

59012LP 

AIR PRESSURE SWITCH CE C6065FH1748B 

9

 

59015LA  

WATER PRESSURE SWITCH 1/8’’ PC 5411 

9

 

73507LA 

HEATING  1/8’’ SENSOR 

9

 

73508LA 

D.H.WATER 1/8’’ SENSOR 

9

 

76631LA 

ELECTRONIC IGNITION BOARD CVI S4565 A 2019B 

9

 

76654LA 

DISPLAY DIGITAL BOARD 2000 SKO6206 

 

9

 

76655LA 

PRINTED CIRCUIT BOARD CVI-M SM 20015 

9

 

86006LA  

SAFETY THERMOSTAT 95°C WATER TB 1NT BN0D095FV 

9

 

86014LA 

WATER PRESSURE GAUGE 40 0-4 G1-8C/DC+  

9

 

95018LA 

LT.10 EXPANSELL VESSEL 13D00010 

9

 

96008LA 

3 BAR PRESSURE RELIEF VALVE 1/2’’ 2809 

9

 

96032LA 

DIVERTER VALVE ATV-03 M.PLEX 561128 

9

 

96034LA 

DIVERTER VALVE MOTOR 561128   

9

 

 

Содержание RSF 30

Страница 1: ...A01A011 B1003 Technical Specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH INSTALLATION AND MAINTENANCE MANUAL FOR GAS FIRED WALL HUNG BOILERS Model RSF 30 E TYPE C ROOM SEALED SEDBU...

Страница 2: ......

Страница 3: ...EM page 3 GENERAL INSTALLATION REQUIREMENTS page 4 BOILER INSTALLATION page 6 ELECTRICAL CONNECTIONS page 8 13 BOILER CONTROL PANEL page 9 STARTING UP THE BOILER FOR THE FIRST TIME page 9 MULTIGAS OPE...

Страница 4: ...ion vessel 2 WARNINGS REGARDING INSTALLATION Warranty expires 12 months from date of installation and in all cases no later than 18 months from date of construction First start up must be performed by...

Страница 5: ...TU h 57774 Heating temperature adjustment C 30 80 Max working pressure heating bar 3 Min working pressure heating bar 0 3 Expansion vessel capacity initial pressure 1 bar Litres 10 Hot water flow rate...

Страница 6: ...USE ORIGINAL RADIANT APPROVED FLUE KIT SYSTEMS FLUE ACCESSORIES AND FLUE DIAPHRAGMS ONLY APPROVED RADIANT FLUE DIAPHRAGMS AND ADJUSTMENT TABLES ARE SUPPLIED WITH RADIANT ORIGINAL FLUE KIT SYSTEMS R C...

Страница 7: ...ework that supplies the boiler must be a 22 mm ininterrupted supply from meter to the isolation cock of the boiler The complete installation must be tested for soundness as described in the above code...

Страница 8: ...re the lowest part of the terminal is fitted less than 2m 6 6ft above a balcony above ground or above a flat roof to which people have access the terminal MUST be protected by a purpose designed guard...

Страница 9: ...lation the boiler is equipped with a fittings kit see fig 3 IMPORTANT Before connecting the heating system pipes carefully clean the system to prevent residual dirt from entering into circulation and...

Страница 10: ...with an Anti Freeze system which comes into operation when the temperature falls to 5 C Heating sensor and 4 C Hot water sensor and protects the boiler down to 10 C external temperature To protect the...

Страница 11: ...strument panel as follows A Turn off the electrical power supply at the mains B Remove the boiler front casing C Undo the two screws on the panel and turn it to the position shown in fig 1 pos 1 D Aft...

Страница 12: ...utral and earth connections have been properly connected make sure the type of gas being supplied is the same as the type for which the boiler has been tested and approved see plate data make sure the...

Страница 13: ...N position and try the ignition procedure once again If the boiler does not start reset boiler and Set the ON OFF switch 1 to OFF and then ON position IMPORTANT should the boiler fail to ignite wait 3...

Страница 14: ...ed d calibrate the new max and min settings for the modulator e replace the gas setting plate that indicates the type of gas and nominal pressure for the boiler When converting the boiler to work with...

Страница 15: ...Y THERMOSTAT 9 ELECTRONIC GAS VALVE VK4105 10 ELECTRONIC IGNITION BOARD 11 EXPANSION VESSEL 12 3 SPEED CIRCULATION PUMP WITH AIR VENT 13 AUTOMATIC AIR VENT 14 HEATING CIRCUIT 3 bar PRESSURE RELIEF VAL...

Страница 16: ...C M1 1 2 3 4 brown light blue IG black black 17 1 PWM 12 light blue 10 11 grey black RS light blue brown 13 14 16 15 L 12 11 9 10 8 7 6 5 4 3 2 N 56 1bar PAC brown black M3 55 brown brown light blue b...

Страница 17: ...tion can be made to either the remote control fig 5 or to the terminal block fig 3 dotted line on the terminals marked SE SE WARNING The remote control connection cable must pass through a channel whi...

Страница 18: ...odulation Check that the electrical connection conforms to the description in the instruction manual for the boiler Check the domestic hot water flow rate and temperature When dismantling the boiler c...

Страница 19: ...230V ES 30 108 G 00 0416 9 43157LP SEALING CLIPS KIT FOR MULTIPLEX GROUP 9 58009LP MAIN HEAT EXCHANGER mod 30 000 kCal h 9 59012LP AIR PRESSURE SWITCH CE C6065FH1748B 9 59015LA WATER PRESSURE SWITCH...

Страница 20: ...LET HAVE BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET E OE ALL RIGHTS...

Отзывы: