background image

                                                                                                          

 

 

          

        

                

        

        

 

 

eXtraheat Limited 
Belmayne House 
Clarkehouse Road 
Sheffield 
S10 2LN 
South Yorkshire 
 
Phone Number 0844 3814115 
Fax Number 01142 309147 
E Mail:

 

[email protected] 

[email protected]

 

Website: 

www.radiant.eu

 

THE  TECHNICAL  DATA  AND  MEASUREMENTS  ARE  PROVIDED  FOR 
INFORMATION  PURPOSES  ONLY  AND  ARE  NOT  BINDING.  THE 
COMPANY  RESERVES  THE  RIGHT  TO  APPLY  VARIATIONS  WITHOUT 
PRIOR  NOTIFICATION.  NEITHER  WILL  THE  COMPANY  BE  HELD 
RESPONSIBLE  FOR  ANY  INACCURACIES  IN  THIS  HANDBOOK 
DERIVING  FROM  PRINTING  OR  TRANSLATION  ERRORS.  E+OEALL 
RIGHTS  RESERVED.  NO  PART  OF  THIS  DOCUMENT  MAY  BE 
REPRODUCED, 

MEMORISED 

IN 

ANY 

FILING 

SYSTEMS 

OR 

TRANSMITTED 

IN 

ANY 

FORM 

WHATSOEVER, 

INCLUDING 

ELECTRONIC,  MECHANICAL,  PHOTOCOPIES,  RECORDINGS  OR  ANY 
OTHER  MEANS  WITHOUT  THE  COMPANY’S  PRIOR  WRITTEN 
APPROVAL. 

 

 

Содержание RK 25

Страница 1: ...0694 RK 18_25_34 RAD ING MAN UT 1104A DIGITECH 2 REGNO UNITO EXTRAHEAT CBD Technical specification by RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RK 18 RK 25 RK 34 Premix condensing boiler ...

Страница 2: ......

Страница 3: ...current standards and where the minimum external temperature does not fall below 10 C The manufacturer will not be held responsible for installation in locations where the temperature falls to below 10 C The boiler is fitted with an antifreeze system If the boiler is installed in a location where there is a risk of freezing the anti freeze system will only come into operation if the power is on an...

Страница 4: ...RATURE CONTROL KNOB 3 NOT OPERATIVE KNOB 4 OUTSIDE TEMPERATURE DISPLAY ONLY WITH OPTIONAL OUTDOOR SENSOR 5 SERVICE BUTTON 6 WINTER MODE SELECTION BUTTON 7 TERMINAL BOARD FOR EXTERNAL WIRING 8 TEMPERATURE ERROR CODE AND OPERATING STATUS DISPLAY 9 TIME CLOCK optional 7 6 5 4 3 2 1 8 9 Fig 1 ...

Страница 5: ... mode press button 6 see fig 1 The boiler will only work for the central heating system The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel The automatic ignition system will light the burner every time there is a demand for room heating In this case the symbol on the control panel will flash Regulating the heating temperature The heating temperat...

Страница 6: ... have been taken call an authorised Service Centre _E01 E01 E01 E01_ Ionisation block Code E01 lit continuously on the display Check that the gas valve on the boiler and gas meter are open and that there is gas in the mains supply or in the tank Switch off then switch on the appliance using switch 1 see Control panel on the control panel When the error code on the display disappears the boiler wil...

Страница 7: ...y on the display Call the Service Centre _E35 E35 E35 E35_ Flame Detection Malfunction Code E35 lit continuously on the display Call the Service Centre N B If the boiler is to be left unused for a long period of time the user must do one of the following Make the boiler safe by disconnecting all the power supplies electricity and gas and draining the heating system and the condensate trap Leave th...

Страница 8: ...ON PURPOSES ONLY AND ARE NOT BINDING THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION ERRORS E OEALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED MEMORISED IN ANY FILING SYSTEMS OR TRANSMITTED IN ANY FORM WHATSOEVER INCLUDING ELECTRONIC...

Отзывы: