1. INSTALLATION
INST
ALLER
1.1.11. GENERATOR INSTALLATION
MINIMAL TECHNICAL SPACES
In order to allow the access inside the boiler for
maintenance operations, you have to respect the
minimum technical spaces indicated in figure 1.
WARNING
The incorrect slopes of the device can
cause the incorrect discharge of condensate by
means of the discharge duct with consequent
condensate stagnation inside the condensate
module.
WARNING
The boiler must be installed only on a
vertical solid wall, able to sustain its weight.
WARNING
The boilers have the electrical
protection degree IPX5D. The outdoor installation
in partially protected environments (platform roof,
balcony - see fig. 2) is allowed in compliance with
the related standards. The Company is not held
liable for installations in environments with a
temperature under –10°C or non-compliant with
the above indications.
H
A
X
Y
B
A
A
A - 200 mm
B - 300 mm
X - 60 mm
Y - 60 mm
H - 1,000 mm
fig.1
fig. 2
1,200 mm minimum
SECTION A-A
balcony/
platform roof