![Radiant EcoSmart ES50LVP Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/radiant/ecosmart-es50lvp/ecosmart-es50lvp_installation-operation-and-maintenance-manual_777141006.webp)
5 |
P a g e
The fan operates at the speed selected on the HEAT CFM switch during the setup. Fan and
pump speed automatically reduce as outdoor temperature rises. Fan CFM may reduce by up to
30% from the HEAT CFM switch setting depending on outdoor temperature.
If the heat generator includes a built-in pump, and it is directly connected to the ecosmart, the
ecosmart will vary the pump automatically. If the system is configured for primary/secondary
pumping and the heat generator includes a pump, the secondary pump can be controlled by
the ecosmart.
Step Modulating Mode
(ecosmart outdoor sensor not installed)
Water temperature is set at the heat generator by referring to the heat generator performance data.
Fan operates at 50% of the HEAT CFM setting for 5 minutes then increases to 75% for a further 5
minutes, then increases to 100% until the thermostat is satisfied. If the pump is controlled by the
ecosmart, its speed will be adjusted accordingly as the ecosmart goes through its stages. If the pump is
controlled by the heat source, it will function according to the heat source control strategy.
Basic Mode
(ecosmart outdoor sensor not installed)
Water temperature is set at the heat generator by referring to the heat generator performance
data. Fan operates at 100% of selected HEAT CFM and pump operates at maximum
speed until
the thermostat is satisfied.