background image

- 6 -

INSTALLATION

· Connect the Cat5 cable to between the ethernet port and the

Series DL221/DL221A

 transceiver’s 10/100BaseT port.

· Connect the fiber optic cable(s) to the 

Series DL221/DL221A

transceiver’s fiber optic port(s). The optical patch cord(s) sent

with the unit may be used if needed.

· Configure the 

Series DL221/DL221A

 transceiver using the

configuration chart on page 7.

· Attach the power cord provided with the unit to the power inlet

on the back of the transceiver. Connect the other end of the

power cord to the AC line voltage source. Verify that the

“power” LED is lit green. Verify the configuration status using

the front panel LEDs

- 11 -

Both Link LED
and 100 BaseTX
LED not lit

Link LED not lit

FDX LED not lit

Copper link not working
at 100M when the
DL221 is connected to
100 Mbps or 10/100
Mbps device

Copper link not working
at 10M when the DL221
is connected to 10M
device (copper side).

The DL221 is not
recognizing full duplex
when DL221 connected
to NWAY full duplex
(copper side).

On the “setup mode switches,”
check that S1 is DOWN or S1 is
UP and S2 is DOWN.
On the “setup mode switches,”
move S6 to the DOWN position,
and move it back to the UP
position after one second.
Check if the connected device is
working properly at 100 Mbps.
Check the interconnection
between the DL221 and the
device.
On the “setup mode switches,”
check that the S1 is DOWN OR
S1 is UP and S2 is UP.
On the “mode setup switches,”
move S6 to the DOWN position,
and move it back to the UP
position after one second.
Check that the connected device
is working properly 10 Mbps.
Check the interconnection
between the DL221 and the
device.
On “setup mode switches,” check
that S1 is DOWN.
On the “mode setup switches,”
move S6 to the DOWN position,
and move it back to the UP
position after one second.
Check that the connected device
is NWAY and full duplex cable.
Check the interconnection
between the DL221 and the
device.

 Problem

Indication

  Corrective Action

Содержание DL221 Series

Страница 1: ...USER S MANUAL Ethernet 10 100 Transceiver Series DL221 DL221A June 1999...

Страница 2: ...shipment Radiant Communications Corporation shall at its sole discretion repair or replace the defective unit Defected units shall not be accepted for return or repair without prior authorization from...

Страница 3: ...thernet component and an optical section which interfaces to the fiber optic cable SPECIFICATIONS Standard Compliance IEEE802 3u 100BaseTx 100BaseFx 10BaseT 100BaseTx Port RJ 45 connector Half full du...

Страница 4: ...a single mode fiber In both cases Radiant s technology allows for extended transmission distances beyond the ethernet standard 13 If the problem persists after carrying out the procedure do the follow...

Страница 5: ...lit FDX LED lit Link LED 100BaseFx not lit The DL221 full duplex is not working when the DL221 is connected to the full duplex without NWAY capability copper side The DL221 half duplex is not working...

Страница 6: ...connected to 10M device copper side The DL221 is not recognizing full duplex when DL221 connected to NWAY full duplex copper side On the setup mode switches check that S1 is DOWN or S1 is UP and S2 is...

Страница 7: ...n change move S6 to down position and move up back after one second 10 TROUBLESHOOTING Problem Indication Corrective Action Main power LED not lit No communica tion on network Link LED not lit No powe...

Страница 8: ...hes have been set to the desired settings the configuration must be locked into the unit This is accomplished using DIP switch 6 After each configuration change move S6 to the down position leave it t...

Отзывы: