- 3 -

GENERAL DESCRIPTION

The Radiant Communications 

Series DL221/DL221A

 transceivers

are used to connect two active ethernet network components

together over a fiber optic cable. Radiant’s unique technology

allows the same transceiver to be used for connecting 10BaseT or

100BaseT components together. The Radiant Communications

Series DL221/DL221A

 transceivers allow for extended fiber trans-

mission distances -- in many cases greater than 100 KM. In addi-

tion, the Series DL221A transceivers allow for bi-directional, full

duplex transmission between ethernet components over a single

optical fiber.

It is convenient to think of the 

Series DL221/DL221A

 transceivers

as having two sections -- an electrical section, which interfaces to

the ethernet component; and an optical section, which interfaces to

the fiber optic cable.

SPECIFICATIONS

Standard Compliance:

  IEEE802.3u, 100BaseTx, 100BaseFx,

     10BaseT

100BaseTx Port

•  

RJ-45 connector

•  

Half/full duplex support via auto-negotiation or manual

•  

100m over UTP/STP 100 ohm cat.5 cable

•  

Auto-polarity correction

•  

MDI-II/MDI-X selection

•  

10BaseT (switch selected)

100BaseFx Port

•  

1300nm SC connectors.  Optional Single Fiber (DL221A)

•  

Distance:  > 100 km (DL221/SMSP)

•  

Full/half duplex switch selected

Diagnostics

Per Channel

•  

Full duplex, Link, Activity - 100BaseFx side

Per System

•  

Power (dual, if redundant PS present)

Controls

Fiber side:  FDX/HDX

Copper side:  10/100 Mbps, FDX/HDX, Autosensing disable/

enable

Environmental/Physical

Power supply:

100/240 VAC.50/60 Hz

Power consumption:

5 W max.

Operating temperature:

0-45

O

C (32-113

O

F)

Storage temperature:

-30O-65)C (22O - 149OF)

Humidity:

10-90% non-condensing

NOTE: 

 Specifications subject to change without prior notice.

Содержание DL221 Series

Страница 1: ...USER S MANUAL Ethernet 10 100 Transceiver Series DL221 DL221A June 1999...

Страница 2: ...shipment Radiant Communications Corporation shall at its sole discretion repair or replace the defective unit Defected units shall not be accepted for return or repair without prior authorization from...

Страница 3: ...thernet component and an optical section which interfaces to the fiber optic cable SPECIFICATIONS Standard Compliance IEEE802 3u 100BaseTx 100BaseFx 10BaseT 100BaseTx Port RJ 45 connector Half full du...

Страница 4: ...a single mode fiber In both cases Radiant s technology allows for extended transmission distances beyond the ethernet standard 13 If the problem persists after carrying out the procedure do the follow...

Страница 5: ...lit FDX LED lit Link LED 100BaseFx not lit The DL221 full duplex is not working when the DL221 is connected to the full duplex without NWAY capability copper side The DL221 half duplex is not working...

Страница 6: ...connected to 10M device copper side The DL221 is not recognizing full duplex when DL221 connected to NWAY full duplex copper side On the setup mode switches check that S1 is DOWN or S1 is UP and S2 is...

Страница 7: ...n change move S6 to down position and move up back after one second 10 TROUBLESHOOTING Problem Indication Corrective Action Main power LED not lit No communica tion on network Link LED not lit No powe...

Страница 8: ...hes have been set to the desired settings the configuration must be locked into the unit This is accomplished using DIP switch 6 After each configuration change move S6 to the down position leave it t...

Отзывы: