background image

- 5 -

FRONT PANEL CONNECTIONS &

INDICATORS

All connections (except power) to the 

DL221/DL221A

 are made at

the front panel. Below is a picture of a 

DL221

 Front Panel. The

DL221A

 is identical, except that the duplex fiber connector is

replaced with a single fiber connector. Please familiarize yourself

with the front panel before attempting to configure the transceiver.

1. Straight/Crossover selector (MDI-II/MDI-X)
2. 10/100BaseTX Connector
3. Twisted Pair Status LEDs

LINK  –  twisted pair link present
RCV   –  receive data on twisted pair port
100TX– Twisted pair is working at 100Mps (off = 10Mps)
FDX   –   Full duplex operation (off = half duplex)

4. Mode Select Switches
5. 100BaseFX (fiber optic) Status LEDs

LINK  –  fiber optic link present
RCV   –  receive data on fiber optic port
FDX   –   Full duplex operation (off = half duplex)

6. Optical Connectors. Typically SC connectors

(other options are available).

DL221 – TX on left, RX on right
DL221A – TX and RX combined onto one fiber

7.    Power LED

Front Panel View

1

2

3

4

6

5

7

- 12 -

FDX LED not lit

FDX LED lit

Link LED
(100BaseFx) not
lit

The DL221 full duplex
is not working when the
DL221 is connected to
the full duplex without
NWAY capability
(copper side)

The DL221 half duplex
is not working when the
DL221 is connected to
the NWAY capability
(copper side).

Fiber link not working

On the “setup mode switches,”
check that S1 is UP and S3 is
DOWN.
On the “setup mode switches,”
move S6 to the DOWN position,
and move it back to the UP
position after one second.
On the “setup mode switches,”
check that the S1 is DOWN OR
S1 is UP and S3 is UP.
On the “mode setup switches,”
move S6 to the DOWN position,
and move it back to the UP
position after one second.
Check that the connected device
is half duplex only.
Check the interconnection
between the DL221 and the
device.
Check that the receive fiber is
properly connected to the
transmit port of the remote fiber
device and the transmit port to
the receive port of the remote
device.
Check that the fiber optic power
is higher than -30 dbm on the
receive fiber connector at the
DL221 end (-26dBm for DL221A)
Check the remote device’s
receive port is properly con-
nected to the transmit fiber optic
port of the DL221.

 Problem

Indication

  Corrective Action

Содержание DL221 Series

Страница 1: ...USER S MANUAL Ethernet 10 100 Transceiver Series DL221 DL221A June 1999...

Страница 2: ...shipment Radiant Communications Corporation shall at its sole discretion repair or replace the defective unit Defected units shall not be accepted for return or repair without prior authorization from...

Страница 3: ...thernet component and an optical section which interfaces to the fiber optic cable SPECIFICATIONS Standard Compliance IEEE802 3u 100BaseTx 100BaseFx 10BaseT 100BaseTx Port RJ 45 connector Half full du...

Страница 4: ...a single mode fiber In both cases Radiant s technology allows for extended transmission distances beyond the ethernet standard 13 If the problem persists after carrying out the procedure do the follow...

Страница 5: ...lit FDX LED lit Link LED 100BaseFx not lit The DL221 full duplex is not working when the DL221 is connected to the full duplex without NWAY capability copper side The DL221 half duplex is not working...

Страница 6: ...connected to 10M device copper side The DL221 is not recognizing full duplex when DL221 connected to NWAY full duplex copper side On the setup mode switches check that S1 is DOWN or S1 is UP and S2 is...

Страница 7: ...n change move S6 to down position and move up back after one second 10 TROUBLESHOOTING Problem Indication Corrective Action Main power LED not lit No communica tion on network Link LED not lit No powe...

Страница 8: ...hes have been set to the desired settings the configuration must be locked into the unit This is accomplished using DIP switch 6 After each configuration change move S6 to the down position leave it t...

Отзывы: