3.1.1. Unlocking Access Levels
The B-RAD X has several diff erent access levels. Table 3.1.1-1 below defi nes the names of access levels, their
use cases, and corresponding codes.
To change access levels:
1. Long press Enter to bring up the Main menu.
2. Use / to navigate to the Lock menu option, press Enter.
3. Input the desired Access code from the chart below.
4. Press Enter to accept the new unlock level or press Back to cancel the entry.
Note:
If entering new calibration values is a requirement, then contact Radial Torque Tools B.V. Customer
Support.
Access
Level
Description and Allowed Menus
Access Codes
0
Lock
The user cannot change the torque setting. Only FWD/REV and Lock Menu are active.
1
Basic
Change Torque value, FWD/REV, View Menu Tool Info, Lock Menu.
2
Advanced
Basic functionality as well as: View and Change Menu Tool Settings, Tool Calibration
3
Distributer
Advanced functionality as well as: Extended Calibration, Extended Tool Statistics.
Contact RAD distributor.
Table 3.1.1-1: Access Levels
3.2. Using the Interface
This section covers the various ways to interact with the interface.
3.2.1. Changing the Target Torque
Ensure you are on the Main Screen (the torque setting is displayed).
To change the torque value:
1. Press and hold (long press) either of the / buttons until a digit starts blinking. The (minus)
button starts the left-most digit blinking. If you press and hold the button again, the selected digit
moves to the right. The opposite happens with the (plus) button.
2. Press the or button quickly to change the digits by one unit at a time. Other digits may be
selected (see Step 1) to fi ne-tune the torque setting.
3. Press the
Enter
button to save the selected torque value once it is set to the desired value. The torque
value will be saved even when the battery is removed.
Note:
A long press is 3-5 seconds.
3.2.2. Toggling Forward and Reverse
To change the Rotational Direction the tool is running in between forward and reverse you must be on the
Main Screen or one of the menus where torque operation is enabled.
Toggling between Forward/Reverse:
• Long press the Back button until the Forward/Reverse indicator LED changes.
Note:
A long press is 3-5 seconds.
3.2.3. Menu Navigation
To enter some menus, an Access Code is required. Refer to Section 3.1 – Access Levels.
• To enter the Menu from the Main Screen: long press
Enter.
• Navigate through the Menu using the / buttons.
• To select the currently displayed menu item: short press
Enter.
• To move up one level in the Menu: double short press
Back.
• To exit the Menu: double short press
Back.
Note:
A long press is 3-5 seconds.
Содержание B-RAD X 7000