8.1 Important information prior to the electrical
connection and installation
Setting the end points on the tubular motor
You must configure the end points of the tubular motor before
installing it and making the final electrical connection otherwise
malfunctions may occur.
It is essential that you set both end points of the tubular motor if no
end points have been set yet.
Parallel connection of electronic tubular motors
A maximum of 3 tubular motors can be connected in parallel to the
Troll Standard (e.g. RADEMACHER electronic tubular motors).
In order to do so, follow the information in the instruction
manual of the tubular motor being used..
Parallel connection of mechanical tubular motors
A cut-off relay is required in order to connect mechanical tubular
motors in parallel.
Requirements for blockage detection
Blockage detection is only operational if a mechanical tubular motor is
connected.
Function of inputs E1 and E2
E1 = UP
E2 = DOWN
i
The external signals to inputs E1 and E2 are only taken into
consideration when the automatic mode is activated.