47
EN
21.6 Menu 6.6 - Total running time and Venetian blinds mode [T]
If the SpeedTimer is being used to control the Venetian blinds,
the controller can be configured correspondingly for this purpose.
The following configurations are possible:
◆
Total running time
◆
Jog mode
◆
automatic slat adjustment
Brief description of total running time
The total running time sets the relay on-period for the respective
direction of travel. This avoids unnecessary waiting times, for
example, as a result of reversing after closing Venetian blinds.
IMPORTANT
The required time for completely opening the roller shutters or
Venetian blinds must be measured with a stopwatch prior to
configuration.
NOTE
If obstacle detection is activated (see page 41), then it is not
necessary to configure the total running time, as the controller
will detect when the end point is reached.
Brief description of jog mode
Jog mode enables Venetian blinds slats to be conveniently
configured. In doing so, the Venetian blinds motor is powered
for as long as the control key is actuated.
In order to conveniently move the Venetian blinds to the end
points, actuate the control key for 1 second longer that the
configured tilting time. Once the key is released, the Venetian
blinds will move to the end point without stopping.