25. Technical specifications and factory settings
External dimensions control unit
[ 1 ]
: 50 x 50 mm x 12
(according to DIN 49075)
Colour:
ultra-white / aluminium
Nominal voltage:
230 V / 50 Hz
Max. switching capacity:
8 (4) A µ (Type 1B)
Standby consumption:
<0.6 W
Extension inputs:
2 (E1 and E2)
Cable size:
1.5 mm²
Installation depth:
32 mm
Permissible ambient temperature:
0 to 40°C
Power reserve for clock in the event
of power failure:
max. 8 hours
Protection class:
II (only for use
in dry areas)
Automatic:
On
Timer periods:
On
Up time:
7:00 hours
Down time:
20:00 hours
random function:
OFF
Switching programme:
1
Blockage detection:
OFF
- Motor type:
2 (45mm / 30 Nm)
- Sensitivity:
230
- Reversing:
OFF
Automatic summer /
winter changeover:
On
Factory settings: