43
increments it to use as default filename for the new data file. The generated
filename can be changed by the user. If file with indicated name exists in the folder,
software prompts to overwrite it, append it or change the filename. If backward
direction is chosen, the profile is mirrored “back to front” (take a look on
processing
on page 63, for details). If profiling passes in “zig-zag” way
(toward, backward, toward, …), then for each backward profile is better to indicate
backward state and software rebuild all profiles in the same direction.
If close the data acquisition mode with the acquired data on the screen, software
replaces it as a separate profile window with name “Profile 1” in the main view for
post-processing and prompt to save it on its close try.
If acquired data is wrong or user doesn’t need it, it can be restarted or canceled.
Software controls the unsaved data and prompt user to save it or cancel.
If during the acquisition user needs to pause sounding (make a pause), press the
Pause
button and will hear the
Paused
sound signal. To continue - press
Continue
or
Mark
button.
Usually, the GPR field work is associated with the data acquisition only and there is
no possibility for the post-processing, that’s why software prompts to shut down PC on the
exit from data acquisition mode.