69
Problem:
“Water leaking from DRV40...”
Check drain plug
Check drain plug and seal for wear and / or
damage. Make sure drain plug and seal are
fitted and tightened adequately. If problem
persists, replace both plug and seal.
Check inlet and outlet connections
Check inlet and outlet thread joints. Check
a correct seal has been made with PTFE
thread sealing tape or liquid sealant. Oil-
based, non-setting joint compounds should
not be used.
DRV body failure
DRV40 replacement required.
Check all DRV seals
Check all internal seals for wear and / or
damage. Clean and refit seals. If problem
persists, replace seals. Only use silicone
based lubricants on rubber seals in
cartridge.
Содержание DRV40
Страница 43: ...43 Step 5 Step 6 ...
Страница 46: ...46 2 5mm HEX 3mm HEX 13mm HEX Step 1 Step 3 Step 4 Step 2 Seals shown 1 1 when printed at Full Scale ...
Страница 47: ...47 3mm HEX Step 5 3mm HEX Step 6 ...
Страница 48: ...48 3mm HEX Step 7 Step 7a Step 7b Seals shown 1 1 when printed at Full Scale ...
Страница 50: ...50 Only use silicone based lubricants on rubber seals A D E E E D B C 1793 215 Seal Pack Step 10 ...
Страница 51: ...51 A D B E C x 2 x 3 Seals shown 1 1 when printed at Full Scale ...
Страница 54: ...54 Calibrate HotEnd Valve Reset Temp 48 C Setpoint 49 C drv40 Rada 6 Wait for the DRV40 to reset ...
Страница 70: ...70 NOTES ...
Страница 71: ...71 NOTES ...