Step 13
Valve Calibration
Must be used after replacing the following parts:
•
Proportioning Assembly
•
PCB
•
Drive Housing
•
Gear Drive Assembly
1.
Turn power on to the reassembled DRV40 and connect to a Laptop/PC device.
2.
Run the
'DRV Programming Software'
and go to the
'Options'
screen.
3.
Click
'Off'
under
'Valve Control'
.
4.
Click
'Calibration Set'
.
5.
Click
'Yes'
to proceed with the calibration and monitor the DRV40 display.