9
Metal Wall Plate
Plastic Wall Plate
Installation
Figure 5
Mounting Bush
Installation to a Shower Cubicle or Laminated Panel
10.
Refer to Figure 5. Drill a 25mm hole and two 5.5mm holes in the panel.
11.
Joint and secure the parallel nipple into the 1/2" BSP female fitting from the
shower mixer outlet. Turn on the water supply and make sure that there are no
leaks.
Note!
Refer to Figure 3 for the maximium projection of the nipple.
12.
Install the plastic wall plate on the nipple. Screw the mounting bush onto the
nipple and tighten until its flange locates in the recess of the wall plate. Place
the metal wall plate in position and secure with the two fixing bolts.
13.
Drill four holes in the panel (through the existing holes in the metal wall plate) to
accept the screws (not supplied) for receiving the metal wall plate. Secure the
wall plate to the panel.
14.
Remove the mounting bush. Joint the exposed end of the parallel nipple. Screw
the mounting bush onto the nipple and tighten until its flange locates in the
recess of the wall plate. Tighten the wall plate fixing bolts.
15.
Refer to Figure 4. Push the shower arm fully over the mounting bush and secure
with the three fixing screws. Push the shower arm trim over the wall plate until
it is secured by the retaining lugs.
Parallel Nipple
All dimensions in millimetres
24
25
5.5
5.5