13
MAINTENANCE
General
Rada products are precision-engineered and should give continued superior and
safe performance, provided:
1.
They are installed, commissioned, operated and maintained in accordance with
our recommendations
2.
Periodic attention is given as necessary to maintain the product in good functional
order.
Maintenance
Maintenance must be carried out in accordance with these instructions, and
must be conducted by designated, qualified and competent personnel.
External surfaces may be wiped clean with a soft cloth, and if necessary, a mild
washing-up type detergent or soap solution can be used.
Warning:
many household and industrial cleaning products contain mild abrasives
and chemical concentrates, and should
not
be used on polished, chromed or plastic
surfaces.
When ordering spare parts, please state product type, i.e. Rada bsr-s 300 shower
fitting and identify part name and number. Refer to the
SPARE PARTS
section.
Procedure - Cleaning or Changing the Spray Plate
(Refer
to Figure 6)
1.
Turn the adjustable spray unit fully anti-clockwise, engage the spray plate key
into the spray plate, unscrew anti-clockwise and remove. Remove the divertor
seat.
2.
Leave the inner 'O' seal in the shower head.
3.
Either clean with a stiff brush or dip into a proprietary inhibited (suitable for plastic
kettles) descalent, used in accordance with the manufacturers instructions.
4.
Do not
use metal probes to clear spray holes.
5.
Refit the divertor seat, screw in (clockwise) the spray plate and tighten with the
spray plate key.