Verbatim Autodialer Specifications
Verbatim Owner's Manual
I-3
I.4
Nonvolatile Program Memory Retention
User-entered programming and voice messages shall be kept intact even during
power failures or when all power is removed for up to ten years.
I.5
Acknowledgment
Acknowledgment of an alarm phone call is to be accomplished by pressing a
Touch Tone® “9” as the alarm call is being received, and/or by returning a
phone call to the unit after having received an alarm call.
I.6
Remote (PLC) Channel Monitoring
Function
The unit shall continuously scan all properly configured Remote Channels. The
unit shall monitor remote channels which physically reside in other industrial
equipment interfaced to the Verbatim via the serial interface. The unit shall be
capable of interfacing to at least two PLC networks simultaneously. The unit
shall be capable of monitoring any PLC data register regardless of register type,
whether digital, analog, input, output or status point. Alarm criteria shall be
settable according data register type. For digital remote channels, alarm criteria
shall be settable for normally ‘0’ or normally ‘1’. For analog remote channels,
both a high setpoint and a low setpoint alarm criteria shall be settable.
Violation of alarm criteria at any remote channel shall cause the unit to go into
alarm state and begin dial-outs. All remote channel alarm criteria shall be
settable either at the front panel of the unit of over the telephone using touch-
tone commands. The unit shall be capable of writing data to any PLC data
register to which writing data is a legal operation. The unit shall monitor any
failure of the active serial communications channels. Upon failure of any
communications channel the unit shall enter the alarm state and begin dial-outs.
The unit shall be capable of transferring data between one remote channel on
one serial communications network and another remote channel on a second
serial communications network. The unit shall also be capable of transferring
data between remote channels on a serial communications network and physical
channels within the unit. The unit shall be optionally upgradable to incorporate
provision for 32, 64 or 96 total remote channels.
Содержание Verbatim
Страница 1: ...Verbatim Owner s Manual Owner s Manual...
Страница 14: ...Overview 1 4 Verbatim Owner s Manual...
Страница 22: ...Installation 2 8 Verbatim Owner s Manual...
Страница 24: ...Programming and Testing 3 2 Verbatim Owner s Manual Front Panel Keys and Indicators Diagram...
Страница 34: ...Recording Voice Messages 4 6 Verbatim Owner s Manual...
Страница 80: ...Using the Alarm Ready Schedule Feature 7 12 Verbatim Owner s Manual...
Страница 82: ...Maintenance Testing and Battery Replacement 8 2 Verbatim Owner s Manual...
Страница 88: ...Verbatim Series SFP Autodialer A 2 Verbatim Owner s Manual Verbatim Series SFP Front Panel Diagram...
Страница 89: ...Verbatim Series SFP Autodialer Verbatim Owner s Manual A 3 Verbatim Series SFP Inside Front Panel ON OFF Switch...
Страница 94: ...Verbatim Series SFP Autodialer A 8 Verbatim Owner s Manual...
Страница 104: ...Analog Signal Input B 10 Verbatim Owner s Manual...
Страница 108: ...Analog Signal Input B 14 Verbatim Owner s Manual...
Страница 110: ...Remote Supervisory Control Output C 2 Verbatim Owner s Manual a RSC Supervisory Remote Control Output Box Diagram...
Страница 114: ...Remote Supervisory Control Output C 6 Verbatim Owner s Manual...
Страница 118: ...Printer Options D 4 Verbatim Owner s Manual...
Страница 126: ...Data Acquisition Central Data Logging E 8 Verbatim Owner s Manual...
Страница 130: ...MODBUS Interface F 4 Verbatim Owner s Manual Electrical Connection Diagram for PLC Network Connection...
Страница 155: ...Cabling Diagrams Verbatim Owner s Manual G 1 G Cabling Diagrams...
Страница 156: ...Cabling Diagrams G 2 Verbatim Owner s Manual G 1 RACO VSER 01 Serial Cable Connection Diagram...
Страница 159: ...Cabling Diagrams Verbatim Owner s Manual G 5 G 4 RACO VMB 2 Serial Cable Connection Diagram Verbatim Verbatim...
Страница 161: ...Cabling Diagrams Verbatim Owner s Manual G 7 G 6 RACO VBB 1 Serial Cable Connection Diagram Verbatim Verbatim...
Страница 162: ...Cabling Diagrams G 8 Verbatim Owner s Manual G 7 VTI 405 505 DCM Serial Cable Connection Diagram...
Страница 166: ...Verbatim Floobydust H 4 Verbatim Owner s Manual DC Power Connection Diagram AJ1 JB8 MINI PLUG...
Страница 174: ...Verbatim Floobydust H 12 Verbatim Owner s Manual Heater Thermostat Mounting and Wiring Diagram...
Страница 183: ...Verbatim Floobydust Verbatim Owner s Manual H 21 Cellularm Cellular Communications Diagram AC Only...
Страница 184: ...Verbatim Floobydust H 22 Verbatim Owner s Manual Cellularm Cellular Communications Diagram 12V DC Only...
Страница 185: ...Verbatim Floobydust Verbatim Owner s Manual H 23 Cellularm Cellular Communications Diagram 24V DC Only...
Страница 188: ...Verbatim Floobydust H 26 Verbatim Owner s Manual Motherboard Component Diagram...
Страница 189: ...Verbatim Floobydust Verbatim Owner s Manual H 27 Jumper Block Diagram...
Страница 192: ...Verbatim Floobydust H 30 Verbatim Owner s Manual...
Страница 200: ...Verbatim Autodialer Specifications I 8 Verbatim Owner s Manual...
Страница 201: ...Worksheets Verbatim Owner s Manual J 1 J Worksheets...
Страница 236: ...Glossary Glossary 8 Verbatim Owner s Manual...
Страница 244: ...Verbatim Owner s Manual...