Filename:  Catalyst Ethernet Addendum 1 1 V1_5 released 

RACO Manufacturing and 

Engineering 

  

Page 9 (21) 

 

 

Figure 1

 

  Hardware connection overview.  

8.

 

EtherNet/IP configuration 

Before you begin

: Ensure that the EDS file (Found on the “Ethernet IP Configuration Tools” CD that was 

shipped with the Catalyst) is copied to the RSLogix 5000 EDS directory (as indicated by Rockwell Automation 
Manual).  The EDS file insures that the RSLogix controller can identify the RACO Ethernet autodialers in the 
Ethernet modules and tags. 

 

To configure the PLC and the EtherNet/IP network the tool RSLogix 5000 is used. Firstly the PLC needs to be 
configured and secondly the EtherNet/IP network. Start the RSLogix 5000 program and follow the steps below. 

 

8.1.

 

PLC configuration 

Either create a new project or use an existing. To create a new configuration, open the file menu and select new. 
In the appearing dialogue select the desired type of PLC, in this case the type 1756-L55 is used. Also enter a 
name for the controller and select chassis type, slot number and project path. To accept the settings press OK. 

Содержание Catalyst

Страница 1: ...06 18 Filename Catalyst Ethernet Addendum 1 1 V1_5 released RACO Manufacturing and Engineering Page 1 21 Addendum to Catalyst Owner s Manual How to configure a Catalyst EtherNet IP with RSLogix 5000 A...

Страница 2: ...Document history Revision Date Description Author 1 00 2014 3 17 Document created Michael Jammal 1 1 2014 4 14 Modifications and verification J Garnett S Pottier 1 2 2014 4 15 Updated M Jammal 1 4 201...

Страница 3: ...EtherNet IP protocols Addendum Table of Contents Document history 2 Introduction 4 1 More info about the network and products 4 2 When should you use this addendum 4 3 Requirements 5 4 Determining Ne...

Страница 4: ...D that is shipped with a new Catalyst Ethernet etcetera can be downloaded from the online support sections of the web site For more information concerning the EtherNet IP network the Open EtherNet IP...

Страница 5: ...Name Type Version Rockwell PLC ControlLogix5000 n a PLC software RSLogix 5000 13 04 00 RACO IPConfig tool RACO IPConfig 2 1 1 1 Catalyst EtherNet IP Network Interface Addendum Catalyst EtherNet IP Eth...

Страница 6: ...will go from 0 to 1 indicating that the communication with the network is impaired and if the Catalyst is programmed to look for this change A bit flipping from 0 to 1 can report the loss of communic...

Страница 7: ...Address Description Size Limitation Catalyst SNA 0xxxx Coil number xxxx 1 bit 1 node 0xxxx 1xxxx Input number xxxx 1 bit 1 node 1xxxx 2xxxx Input register number xxxx 16 bit 1 node 3xxxx 3xxxx Output...

Страница 8: ...nk Similarly when addressing the input register 3xxxx allow for two consecutive 16 bit words keeping in mind the word is reserved but not used Hence consecutive addressing of both Input and Output Reg...

Страница 9: ...r can identify the RACO Ethernet autodialers in the Ethernet modules and tags To configure the PLC and the EtherNet IP network the tool RSLogix 5000 is used Firstly the PLC needs to be configured and...

Страница 10: ...Saved 2014 06 18 Filename Catalyst Ethernet Addendum 1 1 V1_5 released RACO Manufacturing and Engineering Page 10 21 Figure 2 Adding the PLC to the configuration...

Страница 11: ...e Ethernet I O module Right click on the I O configuration directory in the navigation list to the left as seen below Figure 3 Adding the Ethernet module Click on new module and select the desired Eth...

Страница 12: ...the settings for the Ethernet module 8 2 EtherNet IP network configuration The second step is to configure the EtherNet IP network and adding the RACO Catalyst EtherNet IP module to the configuration...

Страница 13: ...module First enter a name for the Catalyst module In the example below we call it RACO Ethernet This name will create a tag in RSLogix 5000 which can be used to access the memory location in the PLCs...

Страница 14: ...e enter 32 in this case stands for 32 instances of 8 bits If we had been using Data INT or Data DINT we would have to recalculate the size to match the data type so Data INT would have been 16 16 bit...

Страница 15: ...Inhibit Module isn t checked After this press finish Now the Catalyst has been added to the I O configuration in RSLogix 5000 The main screen will look as follows Figure 10 The main screen when the c...

Страница 16: ...t Ethernet Addendum 1 1 V1_5 released RACO Manufacturing and Engineering Page 16 21 Select Go Online from the Communications menu Figure 12 Opening the online window A new window appears select Downlo...

Страница 17: ...for the same I O size and IP settings as in the PLC configuration The configuration of the IP settings and the I O sizes is described in the two following chapters In the subsequent two chapters the...

Страница 18: ...see image below Figure 15 The RACO IPConfig tool The program scans the network for RACO Gateway Ethernet modules The settings can be configured manually or the DHCP function can be used For the RACO G...

Страница 19: ...the Modbus RTU side of the network 10 1 Monitoring the tags First go online and switch to Remote Run on the PLC To monitor the tags open the Controller Tags window and go to monitor tags Three tags n...

Страница 20: ...thernet cable into Ethernet outlet Select protocol Ethernet then click Ethernet Configuration This will bring up RACO IPConfig which must be in the same directory as Alarmware Use Raco IPConfig tool t...

Страница 21: ...et up a heartbeat channel to monitor communications recommended Select a channel for example channel 56 SNA 1 2 01992 Alarm on 1 Raw Value 0 reported as 0 Note To reset Catalyst to Factory Defaults Tu...

Отзывы: