3156B User Manual
Getting Started 1-6
Racal Instrument © 2005
WAVEFORM
GENERATOR
3156B
FAIL
ACCESS
CHANNEL 1
CHANNEL 2
MAIN
SYNC
SYNC
MAIN
TRIG
REF
OUT
OUT
DIG
DIG
Figure 1-2 3156B Front Panel
Main Output -
Channel 1 and 2
The main output connectors output fixed (standard) waveforms to
25MHz, user (arbitrary) and sequenced waveforms with sampling
clock to 200MS/s. Output source impedance is 50
Ω
, hence the cable
connected to this output should be terminated with 50
Ω
load
resistance. If the output is connected to a different load resistance,
determine the actual amplitude from the following equation:
The output amplitude is doubled when the output impedance is above
roughly 10k
Ω
.
(
)
V
V
out
prog
=
+
2
50
50
Ω
Ω
R
L