5. Confirm the following hardware setup is displayed on the “PC Settings” tab.
Now select the COM port the Digi
®
XBee USB is connected to, and click the “Open
Com Port” button. The message “Radio Found” is displayed to indicate that you
selected the correct COM port. The ZigBee parameters (firmware version, operating
channel, PAN ID) for the Digi
®
XBee USB will be displayed in the “Radio Parameters”
box. Go to
Control Panel > System > Hardware > Device Manager > Ports
on your
PC if you need help in identifying the USB COM port.
6. Any ZigBee devices discovered will be displayed in the “Devices Discovered” window
to the right.
If the utility times out and no ZigBee devices are displayed, you will have to reconfig-
ure the Digi
®
XBee USB and recompile the sample program once you make sure the
BL4S230 is powered up. The timeout may occur if you are doing development simulta-
neously with more than one ZigBee coordinator. Appendix F explains the steps to
reconfigure the Digi
®
XBee USB.
•
115200 baud
•
Hardware flow control
•
8 data bits
•
No parity
•
1 stop bit