19724 MICROWAVE SENSOR FOR D10
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
SENSOR COVERAGE DIAGRAM
Below diagrams represent best average coverage from lab testing. Actual
coverage may vary as metal on the fixtures can interfere with microwaves from
the sensor
Ceiling mounted detection pattern (m)
ce
ili
ng
m
ou
nt
ing
h
ei
gh
t (
m
)
6
0
5
10%
30%
50%
75%
100%
OPERATION
Multi-level Dimming:
•
100% light
•
Dimmed to: 10, 20, 30, 50*%
*50% not on remote
•
Off
Cut Off Time Adjustment:
•
Once room is vacated, light dims to selected % after
chosen hold time elapses
Daylight Sensing:
•
Surrounding natural light keeps fixture light off until
room is occupied and natural light levels drop to
selected level
8 Hour* Manual Mode:
•
Turn fixture off-on 3 times within 3 seconds
•
Green LED on antenna will flash and fixture will flash 3
times if done correctly
•
Fixture will remain 100% for 8 hours, then sensor will
come on automatically
•
To cancel, turn the fixture off-on within 1 second
*Times out after one 8-hour cycle
Ambient Daylight Threshold*:
•
Turn fixture off-on 2 times within 2 seconds
•
Green LED on antenna will flash slowly for 5
seconds and fixture will blink twice if done correctly
•
Surrounding fc will be measured and recorded for 1
second
•
Green LED on antenna and fixture will light for 10 sec-
onds to indicate successful fc recording
•
Most recent fc measurement overwrites any prior
*DIP settings (pg 1) and ambient lux overwrite eachother depending on latest action
Scene Mode:
•
100% detection range and 10% cut off dimming
Scene 1 (SC1):
1 min hold-time, 10 min cut off period,
.2 fc daylight sensor
Scene 2 (SC2):
5 min hold-time, 10 min cut off period,
.2 fc daylight sensor
Scene 3 (SC3):
10 min hold-time, 30 min cut off
period, 1 fc daylight sensor
Scene 4 (SC4):
10 min hold-time, always on bi-level
cut off period, 5 fc daylight sensor
SENSOR TECHNICAL DATA
Capacitance Load:
400W at 120V, 800W at 230V, 1000W at 277V
Operating Temperature:
-20°C to +60°C (-4°F to +140°F)
Relay:
Zero-cross relay
Maximum Mounting Height:
5m
Customizable Detection Area:
10, 50, 75 or 100%
Time Delay:
5s, 30s, 1min, 5min, 10min, 20min, 30min
Cut Off Period:
0s, 10s, 1min, 5min, 10min, 30min, 1hr, Bi-Level
Cut Off Dimming Level:
10, 20, 30, 50%
Cut Off Power:
Less Than 1W
Daylight Threshold:
About .2-5 fc or Disabled
Sensor Principle:
High Frequency
Microwave Frequency:
5.8GHz +/- 75MHz
Microwave Power:
<0.2mW
Detection Range Max:
16m across, 10m high
Detection Angle:
About 30 to 150 degrees
9
0
4
10%
30%
50%
75%
100%
W
al
l m
ou
nt
ed h
ei
gh
t (
m
)
Wall mounted detection pattern (m)
Fig. 3
Fig. 4
Содержание HALV
Страница 5: ......