background image

INSTRUCTIONS

 

HALV Indoor Architectural-Grade LED Wall Sconce

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

FIG.3

Wall box is installed before sheetrock

.

1.  Remove 

Driver/LED/Wall plate

 assembly by loosening 

4 phillips head screws as shown in 

Figure 1

. No need to 

completely remove screws, keyhole slots provided. Retain 

Hanger

. Unplug connectors (if E2, E2/MVS, E2, E2/BL, or E2/LC) 

and put Driver/LED/Wall plate aside.

2.  Install 

Nailer Bars

 into wall box as shown in 

Figure 2

.

3.  Locate the wall box in the desired position between the studs 

and affix using 

Nailer Bars

.

4.  Tighten 1 phillips head locating screw shown in Figure 2 to hold 

wall box in position on the 

Nailer Bars

.

5.  Run wire to box.

Wall box is installed after sheetrock.

1.  Remove 

Driver/LED/Wall plate

 assembly by loosening 

4 phillips head screws as shown in 

Figure 1

. No need to 

completely remove screws, keyhole slots provided. Retain 

Hanger

. Unplug connectors (if E2, E2/MVS, E2, E2/BL, or LC/E2) 

and put Driver/LED/Wall plate aside.

2.  Discard 

Nailer Bars

.

3.  Move 

Stop Brackets

 from end to side and add 

Sheetrock

 

Clamps

 as shown in 

Figure 3 

(on following page).

4.  Using the template provided, cut opening in sheetrock. Leave 

at least ¾” between box and stud.

5.  Run wire to box.
6.  Place 

Wall Box

 in opening and tighten 4 phillips head screws 

to secure 

Wall Box

.

FIG.1

`

FIG.2

Hanger

Sheetrock Clamp

Stop Bracket 

after relocation. 

Move both

Stop Bracket screw 

after relocation 

Stop Bracket

before relocation

Stop Bracket screw

before relocation

Nailer Bar

Tighten to secure

in sheetrock

Hanger

Driver/LED/Wall

plate assembly

DO NOT TOUCH LEDs

Insert 

screwdriver

though hole to 

loosen screw

4 places

Hanger

Nailer bar

Stop Bracket

Discard for new

work install

Tighten this locating screw

to hold box in place

NEW CONSTRUCTION INSTALLATION

 

(models w/wall box)

REMODELER INSTALLATION

 

(models w/wall box)

Содержание HALV

Страница 1: ...s the following protocols Triac and ELV at 120V ONLY For 0 10V dimming connect purple wire to the V DIM lead and the grey wire to the V DIM lead This fixture is damp listed and suitable for indoor applications on walls Driver is 120V 277V and 50Hz or 60 Hz HALV Mounting the fixture on a standard 4 x 4 J BOX This fixture is damp listed and suitable for indoor applications on walls 1 Loosen the 4 dr...

Страница 2: ... to box Wall box is installed after sheetrock 1 Remove Driver LED Wall plate assembly by loosening 4 phillips head screws as shown in Figure 1 No need to completely remove screws keyhole slots provided Retain Hanger Unplug connectors if E2 E2 MVS E2 E2 BL or LC E2 and put Driver LED Wall plate aside 2 Discard Nailer Bars 3 Move Stop Brackets from end to side and add Sheetrock Clamps as shown in Fi...

Страница 3: ...e over the Driver LED assembly with the phillips head mounting screw at the top See Figure 5 2 Inset the lens frame from the bottom with the bottom flush against the wall See Figure 5 3 Tilt the top of the lens frame to the wall 4 Make sure the frame is flush against the wall and tighten mounting screw at the top using a 5 64 hex key LENS FRAME INSTALLATION Driver LED Assembly DO NOT TOUCH LEDs Mo...

Страница 4: ...t at 888 RAB 1000 or email marketing rablighting com Easy Answers rablighting com Visit our website for product info Tech Help Line Call our experts 888 722 1000 e mail Answered promptly sales rablighting com Free Lighting Layouts Answered online or by request 2019 RAB LIGHTING Inc Northvale New Jersey 07647 USA DIMENSIONAL DRAWINGS LENS FRAME ASSEMBLY MODELS WITH BACK BOX LENS FRAME ASSEMBLY STAN...

Страница 5: ......

Страница 6: ...rred to as R for right position and L for left position when looking at sensor in orientation shown in Fig 2 in which all switches are R See Fig 1 and 2 for each setting s corresponding switches Setting options for each category are noted in parenthesis below Factory Settings designated in bold for each category Detection Area Time Delay how long lamp remains on at 100 after last recognized motion...

Страница 7: ... Green LED on antenna will flash slowly for 5 seconds and fixture will blink twice if done correctly Surrounding fc will be measured and recorded for 1 second Green LED on antenna and fixture will light for 10 sec onds to indicate successful fc recording Most recent fc measurement overwrites any prior DIP settings pg 1 and ambient lux overwrite eachother depending on latest action Scene Mode 100 d...

Страница 8: ...or 30 for dimmed light output after time delay passes Note These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2016 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info e...

Отзывы: