All wiring MUST comply with local 
electrical codes and should be installed 
by qualified electrician.

• 

Read entire Installation Manual before 
proceeding.

TURN OFF POWER BY REMOVING 
POWER FUSE OR TURNING OFF CIRCUIT 
BREAKER BEFORE INSTALLATION.

• Total lighting load must not exceed:

 

5 amps, 500 watts incandescent quartz 
when sensor is used remotely (250 watts 
when floodlights are mounted ot sensor) 
or 100 watt fluorescent at 120 volts or 5 
Amps, 450 Watts LED at 120 Volts with 
0.8pF driver or 5 Amp, 300 Watts LED at 
120 Volts with 0.5pF driver.  
To switch more wattage, an electrician 
can install an additional relay.

• Line Carrier Remote Control Systems 

such as X-10, Leviton or Radio Shack are 
incompatible with sensors and cause 
false activations.

• Do not install on circuits feeding motor 

loads such as kitchen appliances, HVAC 
equipment, washer/ dryer or garage door 
openers.

• Sensor functions best when movement is 

across its detection pattern, not towards 
the sensor. 

• Mount 6’-10’ high for optimum range and 

direction. 

Less Sensitive

More Sensitive

TURN OFF POWER BY REMOVING FUSE 
OR TURNING OFF CIRCUIT BREAKER 
BEFORE INSTALLATION.
1. Tuff Dome sensors should be wall 

mounted.

2. Remove plastic lens cover and Tuff 

Dome sensor assembly from mounting 
plate.

3. Tuff dome can be mounted to 4” round 

outlet boxes, octagon, single rectangular 
or Gem boxes.

4. Place the rectangular gasket supplied 

between the Tuff Dome mounting plate 
and the chosen outlet box.

5. Put mounting plate on chosen outlet 

box and match up holes. Tap out 
knockouts if necessary.

6.

 If using floodlights, screw the threaded 

arm(s) of each floodlight into the die 
cast housing of the Tuff Dome. Leave 
the locknuts and arm screws loose until 
ready to aim. Always mount the sensor 
below lights. 

7. Bring power leads, sensor leads and 

floodlight leads into outlet box.

8. Make sure outlet box is properly 

gounded.

9. Strip 1/2” of insulation from all leads. 

Connect as shown in wiring diagram.

10. Twist on wire nuts, secure with 

electrical tape.

11. Put round gasket between sensor 

assembly and mounting plate. 
Use  keyhole alots to secure sensor 
assembly to mounting plate. Use 
silicone sealant around all openings. 

12. Aim sensor. Perform Walk Test, see 

section, “Aiming and Walk Testing” on 
page 9.

13. Put lens cover back on Tuff dome 

using (3) screws.

14. Turn on power.

Tuff Dome Assembly

Basic Wiring Diagram

Vandalproof Installation

Screws:
Tuff Dome sensors are shipped with 
stainless steel screws holding the plastic 
lens on the front of the sensor. If desired, 
you may install vandalproof screws and 
tighten with Hex wrench (screws and 
wrench supplied).
Plugs:
Tuff Dome has three 1/2” plugs in the 
die cast housing of the sensor. A unique 
feature of these plugs is that you may 
insure a vandalproof case by removing 
the plugs, tuning them around, and re-
installing the plugs from the back of the 
Tuff Dome sensor (if you are not using 
the holes for lighting fixture).

The reversed plugs do not have 
screwdriver slots which reduce the 
chance of tampering.

Gasket

Gasket

Mounting Plate

Sensor assembly

Lens Cover

Mounting Plate

knockouts 

(not drilled)

Indentation 

for seating  

Tuff Dome

5

4

Caution

Assembly and Wiring

Содержание Tuff Dome

Страница 1: ...InstallationManual Tuff Dome Vandal Resistant Outdoor Motion Sensor 1...

Страница 2: ...on Withstands up to 3000 Volts Manual Override Double flip wall switch logic prevents activation by short power outages Resets to auto at dawn No extra wiring needed LED Detection Indicator Glows red...

Страница 3: ...osen outlet box and match up holes Tap out knockouts if necessary 6 If using floodlights screw the threaded arm s of each floodlight into the die cast housing of the Tuff Dome Leave the locknuts and a...

Страница 4: ...r part of the lens or using the bottom mask on the Lens Mask Kit provided What does Manual Override do Keep lights on by flipping the wall switch two times within 5 seconds Sensor resets to auto mode...

Страница 5: ...time test that all fixtures and lamps function properly For the next 3 minutes the sensor will keep lights on for 5 seconds each time it detects movement in its Detection Zone The sensor will change t...

Страница 6: ...nt across its pattern more quickly To fix move the sensor 5 Check that movement far away and directly towards sensor is not entirely within one Detection Pattern finger Problem Sensor will not detect...

Страница 7: ...n symbol 3 Check that lights from other sources such as adjacent porch lights garden lights streetlights or lights from inside the house are not in the sensor s view See 1 under Lights Turn Off Too Qu...

Страница 8: ...llowing warranties apply to RAB Lighting Inc RAB products that meet all of the following conditions a the product was purchased by the contractor or end user from an authorized RAB distributor who pur...

Страница 9: ...Product Help Tech Help Line Call our experts 888 RAB 1000 2015 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answered promptly sales rabweb com T...