Location Considerations:

• Choose a location from which the 

sensor can “see” all the paths of 
movement that will be illuminated by 
its lights.

• Tuff Dome is for wall mounting only.

• Sensor functions best when the 

direction of expected movement 
is across its detection pattern, not 
towards the sensor.

• Locate 6-10’ high for optimum range 

and detection. Lower mounting height 
will reduce range.

Detection Pattern:

• The sensor has a “Double Look Down” 

Lens with one “Look Out” zone and 
two “Look Down” zones, for excellent 
detection both at long and close range.

Detection extends out a maximum of 
30 feet and is 180º wide.

• To reduce the Detection Pattern length, 

aim the sensor down

To Adjust Aiming:

1. 

Remove lens cover

2. 

Tilt sensor to desired angle

3. 

Re-install cover 

• To reduce Detection Pattern width, 

mask the sides of the lens with the 
Lens Mask Kit provided or opaque 
weatherproof tape.

• If sensor is mounted by a doorway at 

the top of stairs, be aware that the 
elevated mounting height may extend 
the sensors range.

• As distance from the sensor increases, 

it will take more movement to be 
detected. For instance, at 10 feet, a half 
step will be enough, while at 30 feet, 
several steps will be necessary. 

8’

Side View

20’

Double Look Down Lens

60’

20’

Top View

Less Sensitive

More Sensitive

9

8

Picking A Location

Aiming and Walk Testing

Test Period:

The sensor has a 3 minute Test Period 

which allows it to be aimed and walk 
tested day or night.

•  For the first 30 seconds, the lights will 

be turned on. During this time, test 
that all fixtures and lamps function 
properly.

•  For the next 3 minutes, the sensor will 

keep lights on for 5 seconds each time 
it detects movement in its Detection 
Zone. The sensor will change to 
Automatic Mode after the 3 minute 
Test Period.

•  If another 3 minute Test Period is 

desired, turn the power off for at least 
10 seconds and back on again.

Walk Test:

The purpose of the Walk Test is to check 

and adjust the coverage pattern.

1. Aim the sensor approximately to cover 

the area you desire. 

2. Start outside the Detection Zone and 

walk across the zone until the lights 
go on. As distance from the sensor 
increases, it will take more movement 
to be detected. For instance, at 10 feet, 
a half step will be enough, while at 30 
feet, several steps will be necessary.

S

T

Start

Finish

Photocell

Turn to moon  

symbol for night 

only

Turn to sun 

symbol for 24 

hour operation 

(lights turn on 

night and day)

3. To reduce range, use the lens masks 

provided or tilt sensor down.Repeat 
steps #2 and #3 until you are satisfied 
with the coverage. 

4. The Time Control is factory set 

between 5-8 minutes. This period 
starts after the movement in the 
Detection Zone ceases. If less time 
is desired, turn the time control 
counterclockwise. For more time, turn 
the control clockwise.

5. The sensor is factory set for night only 

operation. To obtain full operation 
24 hours per day, turn the Photocell 
Control fully clockwise to the sun 
symbol. Intermediate settings will 
allow the sensor to operate earlier or 
later at dusk.

6. Your sensor is ready for operation. See 

the Technical Tips pages if additional 
help is needed.

Control Panel:
Turn controls gently using the 
adjustment tool provided. Do not force 
past stops.

Содержание Tuff Dome

Страница 1: ...InstallationManual Tuff Dome Vandal Resistant Outdoor Motion Sensor 1...

Страница 2: ...on Withstands up to 3000 Volts Manual Override Double flip wall switch logic prevents activation by short power outages Resets to auto at dawn No extra wiring needed LED Detection Indicator Glows red...

Страница 3: ...osen outlet box and match up holes Tap out knockouts if necessary 6 If using floodlights screw the threaded arm s of each floodlight into the die cast housing of the Tuff Dome Leave the locknuts and a...

Страница 4: ...r part of the lens or using the bottom mask on the Lens Mask Kit provided What does Manual Override do Keep lights on by flipping the wall switch two times within 5 seconds Sensor resets to auto mode...

Страница 5: ...time test that all fixtures and lamps function properly For the next 3 minutes the sensor will keep lights on for 5 seconds each time it detects movement in its Detection Zone The sensor will change t...

Страница 6: ...nt across its pattern more quickly To fix move the sensor 5 Check that movement far away and directly towards sensor is not entirely within one Detection Pattern finger Problem Sensor will not detect...

Страница 7: ...n symbol 3 Check that lights from other sources such as adjacent porch lights garden lights streetlights or lights from inside the house are not in the sensor s view See 1 under Lights Turn Off Too Qu...

Страница 8: ...llowing warranties apply to RAB Lighting Inc RAB products that meet all of the following conditions a the product was purchased by the contractor or end user from an authorized RAB distributor who pur...

Страница 9: ...Product Help Tech Help Line Call our experts 888 RAB 1000 2015 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answered promptly sales rabweb com T...

Отзывы: