![R.V.R. Elettronica PJ3500M-C Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/r-v-r-elettronica/pj3500m-c/pj3500m-c_user-manual_3098314022.webp)
14
/ 34
User Manual
Rev. 1.0 - 05/04/13
PJ3500M-C & PJ5000U-K
@230V
single phase
@230V
three phase
@400V
three phase
AUX OUT FUSE
(chap. 6.2 – position [9])
(1x) F6,3T tipo
5x20
(1x) F6,3T tipo
5x20
(1x) F6,3T tipo
5x20
SERVICE FUSE
(chap. 6.2 – position [10])
(1x) F6,3T tipo
5x20
(1x) F6,3T tipo
5x20
(1x) F6,3T tipo
5x20
MAINS FUSE
(chap. 6.2 – position [1])
(3x) F25T tipo
10x38
(3x) F20T tipo
10x38
(3x) F16T tipo
10x38
Table 5.1:
Main Fuses
Install the amplifier in a standard rack for 19” modules.
Assemble the modules by inserting them one on top of the other.
Make the connections between the
PS
module and the
RF
module using the cables
supplied with the machine:
• Data connection by means of cable with DB37 connectors (PS-RF
Interconnection)
• Ground connection between each module chassis