5. Quick guide for installation and use
This section provides a step-by-step description of equipment installation and
configuration procedure. Follow these procedures closely upon first power-on
and each time any change is made to general configuration, such as when a new
transmission station is added or the equipment is replaced.
Once the desired configuration has been set up, no more settings are required
for normal operation; at each power-up (even after an accidental shutdown),
the equipment defaults to the parameters set during the initial configuration
procedure.
The topics covered in this section are discussed at greater length in the next
sections, with detailed descriptions of all hardware and firmware features and
capabilities. Please see the relevant sections for additional details.
IMPORTANT:
When configuring and testing the transmitter in which the equipment
is integrated, be sure to have the Final Test Table supplied with the equipment ready
at hand throughout the whole procedure; the Final Test Table lists all operating
parameters as set and tested at the factory.
5.1 Preparation
5.1.1 Preliminary checks
Unpack the amplifier and firstly check that it has not been damaged in any way
during transport. Make sure that all the connectors and controls on the front and
back panels are in good order.
Check the default setting of the type of power supply for this machine on the back
of the
PS
module, which may be:
•
single-phase
230 V, +10% -15%
•
three-phase
230 V, +10% -15%
•
three-phase
400 V, +10% -15%
Suggestion:
Specify the type of power supply at order placement: the machine
will be delivered to you configured according to your requirements.
Check, if need be, that the fuses are installed, in good working order and accessible
on the back panel of the PS module. The required fuse values are as follows: