PJ2000M-C, PJ2500M-C & PJ3000M-C

16 / 40

User Manual

Rev. 1.5 - 09/10/09

The system resets the alarm counters automatically after thirty minutes of operation, 

i.e. the user need not do anything, if the amplifier does not trigger any alarms or 

after the machine the machine has been turned OFF and then back ON.

  5.4.1  RF module auxiliary protection

The amplifier’s RF module contains a second microcontroller that manages local 

measurements  and  carries  out  auxiliary  protection  functions  of  the  machine 

together with the main protection system. This microcontroller card indicates its 

interventions via the LEDs of the RF module. 

A  delivered  power  automatic  back-off  mechanism  is  envisaged  for  excess 

temperature,  SWR  or  current  absorbed  by  a  MOSFET  module.  The  yellow 

FOLDBACK LED indicates this case.

A FAULT signal is triggered (red LED) when a fault occurs that stops the power 

amplifier. This situation is signaled to the machine’s main microcontroller as well 

and triggers a lock situation (FAULT).

The LED FUSE BLOWN indicates that one of the fuses that protects the power 

supply of the MOSFET modules has blown. In this case the machine keeps running 

as usual (obviously without the contribution of the module) even if it is advisable 

to single out and clear the cause for the malfunction and replace the fuse as soon 

as possible to fully restore the machine’s working efficiency.

 

Note: 

Il pulsante RESET sul modulo PS resetta anche le protezioni ausiliarie del 

modulo RF.

  5.4.2  Power Supply Units

Three power supply units, which work in parallel mode, power the machine. Should 

one of the power supply units malfunction, the machine automatically reduces the 

delivered power down to a value compatible with the current deliverable from the 

surviving power supply. This situation is indicated by the “P.S. ALARMS” LEDs on 

the front panel of the PS module.

Содержание PJ1000M-C

Страница 1: ...Manufactured by Italy PJ2000M C PJ2500M C PJ3000M C User Manual Volume 1...

Страница 2: ...ng photocopying recording or by any informa tion storage and retrieval system without written permission of the copyright owner File Name PJ2000M C_PJ2500M C PJ3000M C_ING_1 5 indb Version 1 5 Date 09...

Страница 3: ...3 5 Quick installation and operating reference 5 5 1 Preparation 5 5 2 Operation 8 5 3 Software 9 5 4 Protection System 15 6 External Description 17 6 1 PS Module Frontal Panel 17 6 2 PS module Rear...

Страница 4: ...PJ2000M C PJ2500M C PJ3000M C ii User Manual Rev 1 5 09 01 09 This page was intentionally left blank...

Страница 5: ...adequate measures Specifications and informations contained in this manual are furnished for information only and are subject to change at any time without notice and should not be construed as a comm...

Страница 6: ...se is absent begin artificial circulation Figure 4 depressing sternum Figure 5 Figure 3 Figure 4 Figure 5 In case of only one rescuer 15 compressions alternated to two breaths If there are two rescuer...

Страница 7: ...alled PS RF amplifier module called RF RF Module PS Module Figure 4 1 PJ3000M C PJ2500M C and PJ2000M C modules Subdividing it into two modules not only makes it easier to handle and assemble the ampl...

Страница 8: ...RF IN TELEMETRY RS232 IIC INTERLOCK 50V AF AMP8 MOSFET BLF278 AF AMP8 MOSFET BLF278 AF AMP1 MOSFET BLF278 AF AMP1 MOSFET BLF278 AF AMP4 MOSFET BLF278 AF AMP4 MOSFET BLF278 AF AMP3 MOSFET BLF278 AF AMP...

Страница 9: ...ngle phase 208 V 15 10 single phase 230 V 10 15 three phase 208 V 15 10 three phase 230 V 10 15 three phase 400 V 10 15 Suggestion Specify the type of power supply at order placement the machine will...

Страница 10: ...9 10 09 Data connection by means of cable with DB37 connectors PS RF Interconnection Ground connection between each module chassis Power supply connection by means of cable coming out of the PS module...

Страница 11: ...internal conductor floats when the amplifier works correctly on the contrary power is delivered and the internal conductor is closed to ground to halt the exciter Connect the RF output to the antenna...

Страница 12: ...h the action of the Automatic Gain Control AGC is disabled 5 2 Operation After having plugged in the power supply socket at the back of the machine power on the amplifier via the switchboard The ON LE...

Страница 13: ...livered from the amplifier reaches the desired value If back off is permanent to set the station s power at a level lower than the maximum rated output first disable the AGC by turning the RF PWR ADJ...

Страница 14: ...ftware and hardware versions A few seconds later the main screenful is displayed indicating the forward and reflected power values Press the ESC key to view the selection screenful from which to acces...

Страница 15: ...nector is set to ground so as to force the connected exciter to a stand by condition this takes place only if the exciter features the interlock option like those produced by RVR and if the associated...

Страница 16: ...ul only two lines can be seen at a time use the UP and DOWN keys to scroll through it 5 3 4 Warning threshold setting menu As mentioned in the introduction the amplifier offers three settable warning...

Страница 17: ...xample the alarm thresholds are as follows PwrGd1 2400 W 80 x 3000 W x mod PJ3000M C 2000 W 80 x 2500 W x mod PJ2500M C 1600 W 80 x 2000 W x mod PJ2000M C PwtGd2 1500 W 50 x 3000 W x mod PJ3000M C 125...

Страница 18: ...t when the amplifier is connected in an RVR transmission system that envisages the use of this protocol Do not change it for any reason whatsoever The main menu may be displayed either in Digital mode...

Страница 19: ...ated by X Y whereas the second one is indicated by Wait The third possibility is that the system does not trigger the protection conforming to a specific parameter this is indicated by Dis Disabled Wh...

Страница 20: ...red LED when a fault occurs that stops the power amplifier This situation is signaled to the machine s main microcontroller as well and triggers a lock situation FAULT The LED FUSE BLOWN indicates th...

Страница 21: ...mplifier is in local control mode 6 FOLDBACK Yellow LED indicating that the foldback function is active automatic reduction of the distributed power 7 CONTRAST Trimmer to regulate the contrast of the...

Страница 22: ...us networking 6 INTERCONNECTION PS RF DB37 connector for interfacement with RF part 7 COM BUS DB15 connector for interfacement with other equipment 8 TELEMETRY DB25 telemetry connector 9 AUX OUT FUSE...

Страница 23: ...erlock 6 Set 4 7 GND GND 8 On Command 9 Set 1 10 WAIT 11 Reset alarm 12 OFF 13 Interlock 14 Temperature 3 9V x 100 15 RF power amplifier current 3 9V x 75A 16 Forward Power 4 3V x F S 17 FAULT 18 Set...

Страница 24: ...9 10 09 6 3 3 I2 C Connector Type DB9 Female 1 NC 2 SDA Serial Data 3 SCL Serial Clock 4 NC 5 GND GND 6 NC 7 NC 8 NC 9 NC 6 3 4 Com Bus Type DB15 male 1 GND 2 485 3 485 4 GND 5 ON OFF C 6 INP PWR 7 ST...

Страница 25: ...4 23 25 26 28 31 33 16 NC 17 AC3 Internally connected with 35 18 NC 20 I TOT 19 AC4 Internally connected with 37 21 F PWR 22 INP PWR 23 GND Internally connected with 1 12 14 15 25 26 28 31 33 24 PS ST...

Страница 26: ...ted 3 FUSE BLOWN Red LED that indicates the presence of one or more broken fuses 4 RF PWR ADJ Power regulation trimmer A G C control 5 ON Green LED indicating that the amplifier is switched on 6 FOLDB...

Страница 27: ...erfacement with PS part 2 DB9 connector reserved for future uses 3 RF IN RF input connector N type 4 RF IN TEST Connector for the drawn not standardized of the modulator input signal 5 PLUG Plug for t...

Страница 28: ...0 I TOT 19 AC4 internally connected with 37 21 F PWR 22 INP PWR 23 GND internally connected with 1 12 14 15 25 26 28 31 33 24 PS STATUS 25 GND internally connected with 1 12 14 15 23 26 28 31 33 26 GN...

Страница 29: ...PJ2000M C PJ2500M C PJ3000M C 25 40 User Manual Rev 1 5 09 01 09 7 7 1 This page was intentionally left blank...

Страница 30: ...PJ2000M C PJ2500M C PJ3000M C 26 40 User Manual Rev 1 5 09 10 09 This page was intentionally left blank...

Страница 31: ...PJ2000M C PJ2500M C PJ3000M C 27 40 User Manual Rev 1 5 09 01 09 This page was intentionally left blank...

Страница 32: ...this chapter Top View of PS secition with PFC 1 2 3 4 6 5 1 PS RF Interface Board SLINPSP2K01 PJ2000M C PJ2500M C SLINPSP2K03 PJ3000M C 2 Surge Protection Board SLSRGPRPJ2K1 3 PFC PFCPSL1000 PJ2000M C...

Страница 33: ...01 09 Top View of PS section with Rectifier only PJ2000M C e PJ2500M C 1 2 3 4 5 6 1 PS RF Inteface board SLINPSP2K01 2 Surge Protection Board SLSRGPRPJ2K1 3 Rectifiers RCTPSL1000 4 Power Supply PSL10...

Страница 34: ...Manual Rev 1 5 09 10 09 Top View of RF section mod PJ3000M C 1 2 3 4 5 1 Low pass Filter Board SLLPFPJ2KLST 2 Amplifier Modules SL046RF1001 3 Fuses Board SLFUSRFPJ4K1 4 Bias Boards SLMTPRTPJ4K1 CPU Bo...

Страница 35: ...K1 4 Bias Boards SLMTPRTPJ2K1 CPU Board CPUPJ2KMC 5 LEDs Boards SLLEDRFPJ2K1 8 1 Power Supply Change To use the amplifier with different types of power supply you should connect the mains power supply...

Страница 36: ...the external power supply plug must have the following characteristics PIN1 of the main connector is connected to Neutral wire PIN2 of the main connector is connected to Phase wire and internally conn...

Страница 37: ...f the external power supply plug must have the following characteristics PIN1 of the main connector is connected to Neutral wire PIN2 of the main connector is connected to Phase R Wire PIN3 of the mai...

Страница 38: ...e the machine Make the JP3 connection on the Rectifier card between PIN 1 and 2 to select 230 Volts or between PIN 2 and 3 for 115 Volts Figure 8 1 Connection for the selection of 115 or 208 230 Volts...

Страница 39: ...supply modules are located in the middle part of the amplifier The power supply units are mounted on a cooling fin to cool the amplifier by forced ventilation The amplifier houses a transformer the i...

Страница 40: ...transformer from which it receives the signals and to which it issues commands This interface card is designed to make the PS part communicate with the RF part and making available the dedicated signa...

Страница 41: ...ve device used in the amplifier modules is a Mosfet 2x BLF278 in PJ3000M C model SD2942 in PJ2500M C model or BLF278 in PJ2000M C model 8 3 2 Wilkinson Splitter and Combiner Both the splitter and the...

Страница 42: ...her one supplies the reflected power 8 3 6 Control Board The control board acts as an auxiliary card for the PROTF card in the PS section should the latter fail to trip due to a malfunction It impleme...

Страница 43: ...can supply an output power of approximately 30W suitable to pilot PJ2000M C and PJ2500M C with a total gain of approximately 15dB The active device utilized in the amplifier modules is a Mosfet BLF17...

Страница 44: ...PJ2000M C PJ2500M C PJ3000M C 40 40 User Manual Rev 1 5 09 10 09 This page was intentionally left blank...

Отзывы: