16
/ 30
User Manual
Rev. 2.0 - 17/02/17
SCML1+1SL ( /V1, /V2 , /V3 & /V4 )
ELETTRONICA
5.2.3 Change Setting
Retry : 10
Start :05m00s
Before:02m00s
TxOff :02m00s
Coax :02m00s
After :05m00s
Exit
Retry
indicates the total number of retry before passing in MANUAL from 0
to 50.
Start
modifies the waiting time to the start from 5 to 60 min.
Before
modifies the waiting time before beginning the exchange from 1 sec to
30 min.
TXOff
modifies the waiting time before beginning the switch off of TX from 1
sec to 30 min.
Coax
modifies the waiting time before beginning the commutation of the
coaxial relay from 5 sec to 30 min.
After
modifies the waiting time before beginning the switch on of TX in antenna
from 5 sec to 30 min.
5.2.4 Function Status
Load : Fault
L-Fan : On
InhPa : Disable
IntAud: Normal
ExtAud: Disable
Exit
Load
shows the dummy load status (if enabled).
L-Fan
shows the status of the fan on the dummy load (if enabled).
InhPa
shows the status of the inhibit signal supplied from the PA in the Gold
configuration (if enabled)
IntAud
shows the status of the internal audio exchange.
ExtAud
shows the status of the external audio exchange (if enabled).