Radio Modem Box
17 / 29
User Manual
Rev. 1.0 - 24/06/04
5.3 Remote Control
All parameters of the device connected to Radio Modem Box that have been enabled
for telemetric control can be monitored on a PC with a suitable modem connection.
The "TELECON" software establishes connection with the station through a phone
line or GSM modem and enables the following remote operations: alarm reset,
transmitter power on/power off, output power reduction, dummy load testing, etc.,
data evaluation to locate possible faults, identification of parts required for repair.
5.4 SMS alarm test procedure
This section describes the test procedure for SMS alarms in a system comprising
PTX LCD with 16-bit CPU.
Initial configuration:
1) Perform the steps described in paragraphs 5.1 and 5.2.
2) Go to the "MODEM" menu of PTX LCD and ensure that state is "Stby"
and provider details (service centre and name) are correct.
3) Go to "TEL N." menu of PTX LCD and ensure that the telephone number
set previously is present.
4) Ensure that PTX LCD power output is greater than the alarm threshold
(e.g.: alarm = 50% , output power > 50%).
5) Ensure that PTX LCD display is set in the "MODEM" menu.