12 / 32
User Manual
Rev. 1.0 - 20/06/08
PJ500C-LCD, PJ700C-LCD & PJ1000light
The bottom line provides instantaneous power reading (997W in this instance);
press button to increase level, press to decrease it. When you have achieved
the desired level, press
ENTER
to confirm and exit the default menu. Please note
that the setting is stored automatically; in other words, if you press
ESC
or do not
press any keys before the preset time times out, the latest power level set will be
retained.
NOTE: This feature prevents the machine from delivering maximum power as
soon as output is enabled from menu 4, or in the event the machine is already
set to
ON
and energised.
2) Ensure that machine is not in a locked-out state. Press the
ESC
key (chap.
6.1) to call up the selection screen (Menu 3). Highlight
Fnc
and press
ENTER
to confirm (chap. 6.1) and access the appropriate menu (menu 4).
If
LOC
is set to
REMOTE
(machine remote control), move cursor to
LOC
and
press
ENTER
(chap. 6.1); label will change to
LOCAL
, i.e. local control operation
mode.
In the same menu, ensure that power limiting is disabled: if
PWR
is set to
OFF
,
i.e. power output is disabled, move cursor to
PWR
. Press
ENTER
(chap. 6.1)
and label will switch to
ON
, i.e. power output enabled.
Press
ESC
(chap. 6.1) twice to go back to the
default menu
(menu 1).
3) Fine tune power setting from menu 2 (see description of item 1b) until achieving
the desired value.
WARNING:Equipment is capable of delivering more than rated output power
(500W for
PJ500C-LCD,
700W for
PJ700C-LCD
or 1000 W for
PJ1000-LIGHT
);
however, never exceed the specified power rating.
NOTE: Exciter drive power setting should never exceed 20W, or it will trigger an
Overdrive Alarm.
NOTE: If power is set to 0 W in the
edit mode
, the INTERLOCK OUT contact
(chap. 6.2) trips and external exciter power is immediately inhibited.
Next, you can review all operating parameters of the machine through the
management firmware.
Normally, the machine can run unattended. Any alarm condition is handled
automatically by the safety system or is signalled by the LED indicators on the
panel or by display messages.
NOTE: Standard factory settings are: output power set to upper limit (unless
otherwise specified by customer) and
OFF
.