54
Water cooler control system
The machine has 3 water cooler control modes.
OFF
-
No power to rear 240V aux power outlet.
ON
-
Water cooler on all the time
The machine will give 240V continuous output to rear power outlet
MODE1
-
Water cooler turned on once arc is struck
The machine will start the water cooler as soon as an arc has been established, it will continue to run for 1
minute after you have finished welding..
To access water cooler menu, press and hold the RIGHT ARROW and HOME button for 3 seconds and re-
lease
-
the following screen will appear. Press arrow buttons to move to option 4
-
Now use control knob
to select desired mode
-
then press HOME button to return to main menu.