37
AC MANUAL
-
HOME SCREEN cont..
REMOTE Options
2T
-
Press trigger to start weld, release to finish weld.
4T
-
Press and hold trigger to start weld at start amps, release trigger to go to
main amps. To finish weld
-
Press and hold trigger to go to end amps, release
and weld will stop. If you wish to abort weld during main amps, quickly tap
trigger and main arc will stop and post flow gas will run.
PEDAL
-
Press foot pedal to start weld, fully depress pedal to get 100% of
amps shown in recommended settings.
I.E If main amperage setting was 120A, on a full depress of pedal you will get
120A, if pedal only pressed halfway you will get 60A
4T+F
-
Torch trigger latch operation same as 4T but with amperage control by
slider / rotary knob on torch handle.
2T+F
-
Torch trigger operation for on/off with amperage control by slider /
rotary knob on torch handle.
4TS
-
Torch trigger latch operation same as 4T with the function to switch
between start and main amperage by quickly tapping trigger during main
amps
-
Ideal for pipe welding where you want to switch to start amps to get
continuous weld bead whilst repositioning or getting new filler rod.
AC PULSE Options
Off
-
No pulse settings in main weld settings screen
On
-
Pulse settings shown in main weld settings screen
ADV
-
Advanced mixed mode pulse AC & DC
SPOT
-
Spot welding with optional stitch time function