background image

 

 

 

 

This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation 
and  only  if  the  unit is  installed  inside  the  continental  United  States,  Alaska,  Hawaii,  and  Canada.  The 
warranty applies only if the unit is installed and operated in accordance with the printed instructions and 
in compliance with applicable installation and building codes and good trade practices. 

BASIC ONE YEAR WARRANTY 

During  the  first  year  after  installation,  we  will  provide  a  replacement  for  any  component  part  of  your  unit  found  to  be  defective  in 
materials  or  workmanship,  including  labour  costs.  Repair  work  requires  prior  approval  by  Kingsman,  labour  costs  are  based  on  a 
predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer. 
(Excluded Components: Accent Light Bulbs, Gasketing and Paint) 

LIMITED LIFETIME WARRANTY 

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted again st 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor  in  exchange  for  the  replacement  part.  Any  labor,  material,  freight  and/or  handling  charges  associated  with  any  repair  or 
replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.  

GENERAL TERMS 

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit 
equal to the 

distributor’s component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given 

in lieu of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit being 
replaced must be made available to our distributor for disposition.  

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime 
Warranty, reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date 
of manufacture plus thirty (30) days.  

We  will not be  responsible for  and  you,  the  user,  will pay  for:  (a)  damages caused by  accident,  abuse,  negligence, misuse,  ri ot,  fire, 
flood, or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or 
any other damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or 
repair of the unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's 
components  (e)  damages  caused  by  failing  to  provide  proper  maintenance  and  service  to  the  unit  (f)  any  expenses  incurred  for 
erecting, disconnecting or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, 
inoperation or inefficiency resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel 
cost whatsoever including additional or unusual use of supplemental electric heat.  

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this 
unit.  We  have  not  made  and  do  not  make  any  representation  or  warranty  of  fitness  for  a  particular  use  or  purpose,  and  there  is  no 
implied condition  of  fitness  for  a  particular  use  or  purpose. We make  no  express  warranties  except  as  stated  in  this  Limited  Lifetime 
Warranty.  No  one  is  authorized  to  change  this  Limited  Lifetime  Warranty  or  to  create  for  us  any  other  obligation  or  liability  in 
connections with this unit. Any implied warranties shall last for one year after the original installation. Some states and provinces do not 
allow the exclusion or limitation of incidental or consequential damages or do not allow limitations on how long an implied warranty or 
condition lasts, so the above limitations or exclusions may not apply to you. The provisions of this limited warranty are in  additions to 
and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.  

Save  this  certificate.  It  gives  you  specific  legal  rights,  and  you  may  also  have  other  rights  which  may  vary  from  state  to  state  and 
province to province.  

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available 
for support and we, in turn support the distributor's efforts.  

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your 
files.  

 

Model No. 

 

Serial No. 

 

Date installed 

 

 

Dealer or Contractor Name:  

 

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit. 

 

The Ultimate in Design, Engineering & Quality 

 

65

Содержание Kingsman Marquis MCVP42N

Страница 1: ...of R Co Inc 2340 Logan Ave Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada January 6 2017 Part 42MCVP MAN14 For Propane Horizontal installations the venting must be an additional o...

Страница 2: ...ece Driftwood Log Set For use with GT Glass Tray 24 MQ42LOG1 8 Piece Driftwood Log Set For use with M42LG Log Grate 25 MQ42LOG2 7 Piece Oak Log Set For use with GT Glass Tray 26 MQ42LOG2 7 Piece Oak L...

Страница 3: ...ls 51 Configuration 3 Remote ON OFF Variable HI LO and Fan 52 Electronic Ignition Lighting Instructions 53 VENTING Vent Termination 54 General Vent Installation 55 Installation of Side Wall Venting 55...

Страница 4: ...keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safet...

Страница 5: ...ce 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning ma...

Страница 6: ...in the living area outside the bedroom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and sh...

Страница 7: ...e with the fan off if a fan is present after the curing of the paint has been completed These odours can last upward to 40 hours of burn time keep burning at a minimum of four hours per use until odou...

Страница 8: ...onal construction contractors and finishers Frame unit with metal studs minimum 20 gauge Wooden studs may be used but may cause drywall screws to pop or pull due to wood studs drying out Minimum of 1...

Страница 9: ...adian National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating t...

Страница 10: ...e of Fireplace Fireplace to be covered with Non Combustibles e g Concrete Board for Flat Wall appearance Qty 4 Nailing Tabs are located on flue side of fireplace Nailing Tab Framing Stud Drywall Non C...

Страница 11: ...of where the stand off locations are These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand offs V...

Страница 12: ...MCVP42 Locating Your Appliance See Mantel Leg Clearances Instruction for the proper placement of fireplace MCVP42 Fireplace Dimensions ISLAND ALL UNITS MAY BE VENTED VERTICALLY PENINSULA 12...

Страница 13: ...additional one foot above the minimum vertical rise off the flue before going horizontal Framed fireplace opening 55 MIN for NG 67 MIN for LP Plus Rise of Per Foot 55 MIN for NG 67 MIN for LP Plus Ri...

Страница 14: ...commended but optional to attach Non combustible facing to framing Combustibles i e Drywall may be installed flush with top of Fireplace Side facing to be installed to standoffs only Note Do not drive...

Страница 15: ...n Step Two Use Drywall to finish face of wall NOTE Drywall will be flush with fireplace face Step 3 A brick tile or other non combustible border may be applied over fireplace face to conceal border Na...

Страница 16: ...terial s that will not combust Check your local codes and regulations to determine whether your mantel is combustible or Non Combustible The advantage of a Non Combustible Mantel is that it can begin...

Страница 17: ...iance must be used Carpet hardwood or laminate may extend 1 inch above the floor of the appliance Minimum Ceiling Height from bottom of fireplace 61 Top from Stand offs 0 Top of 90 Bend in minimum Enc...

Страница 18: ...cal from top to bottom Hook lower clip onto glass door frame Press down and push upper clip under top glass door frame Screens shown locked in place Clips First install smaller end screen Then install...

Страница 19: ...Glass Heat Deflectors to install Porcelain Liners WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may re...

Страница 20: ...move Baffle Heater Rated Units or Deflectors Decorative Units Refer to Baffle Removal Deflector Removal sections of manual 2 Orient tabs in upper firebox as shown 3 Insert Liner into Firebox 4 Bend Ta...

Страница 21: ...o ledge at top of firebox Replace end screw first Replace 4 remaining screws ZCV42MCVP Deflector Removal Decorative Units To Remove Deflectors Remove 2 DT Screws holding each Deflector in place To Rep...

Страница 22: ...t Area Must Not Be Covered The following items can be used with the Glass Tray ULK3 Light Kit MQLOG1 MQLOG2 M42LOG3 RBCB1 Cannonballs VLBIT4 or VLBIT6 Decorative Glass MQSTONE MQROCK2 or MQROCK3 MQEMB...

Страница 23: ...ate to end of burner tray with screws To Remove 1 Remove screws holding Grate Assemblies in place 2 Remove screws holding Grate Plate in place 3 Remove from firebox Contents of Kit 1 2 Log Grates 2 2...

Страница 24: ...GT Glass Tray 2 3 4 5 6 8 7 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damag...

Страница 25: ...or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 2 5 6 8 1 3 4 7 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulati...

Страница 26: ...GT Glass Tray 2 3 4 5 6 7 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage o...

Страница 27: ...ailure to use only parts specifically approved with this appliance may result in property damage or personal injury 1 3 1 4 2 7 5 6 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wo...

Страница 28: ...ith GT Glass Tray 2 3 4 5 6 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage...

Страница 29: ...s specifically approved with this appliance may result in property damage or personal injury 1 8 PILOT Place 350 Embers from M42LG in Burner Tray Place Insulation Wool from M42LG in Burner Tray Place...

Страница 30: ...ening Remove glass door first NOTE When using a remote control the 51 UHS Box must be used Batteries for Remote Receiver can be changed by lifting 51 UHS up through opening 51 UHS can be inserted remo...

Страница 31: ...black and red wires at transformer or plug black and red transformer wires together if 120V receptacle will be switch controlled REFER TO COMPONENT LOCATIONS SECTION OF MANUAL FOR TRANSFORMER PLACEME...

Страница 32: ...onged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing contr...

Страница 33: ...bjects MQ Glass can be placed directly on Burner and on Glass Tray MQ Ember can be placed directly on Burner Only Lava Rock Supplied with Base Unit CANNOT be placed on Burner Place Lava Rock in channe...

Страница 34: ...ce Maximum amount 10lbs on Burner Tube and Burner Tray 15lbs on Glass Tray 25lbs Max total MQG5W Decorative Glass 1 2 White MQG5A Decorative Ember Glass Cobalt Blue MQG5B Decorative Ember Glass Black...

Страница 35: ...be used on some installations If sooting occurs change position of or remove affected objects MQEMBER To be placed directly on Burner and Burner Ports Place these glowing ember chunks randomly May be...

Страница 36: ...door in lower latches at an angle of between 15 and 30 degrees 3 Swing door up and pull top latches over door lip at each corner 4 Replace Access Cover below Glass Door 30 15 WARNING Wait until unit...

Страница 37: ...glass Wear gloves Removal of Large Glass Doors 1 Remove the door by unlatching the 2 top latches Simply place 2 fingers in the grooves and pull and lift upward slightly 2 Once the top of the door is...

Страница 38: ...ny pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any...

Страница 39: ...rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter butt...

Страница 40: ...ge Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Rep...

Страница 41: ...e main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the...

Страница 42: ...lot Orifice See Pilot Conversion and Hi Lo valve regulator by following instructions supplied with the Conversion Kit Refer to Gas Specifications Chart for inlet pressures and input ratings Clock mete...

Страница 43: ...ector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sheet fo...

Страница 44: ...Gas Conversion for Modulator PART C 44...

Страница 45: ...anual Then refer to Burner Removal instructions above to remove burner Remove fourteen 14 screws around edge of Burner Pan Carefully work the burner pan loose lift the assembly upward to remove it fro...

Страница 46: ...Switch Remote Receiver Module IPI Module Fan Control Module UHS Box Cover Backup Battery Pack Modulating Servo Motor Is an add on valve component that permits HI LO functionality to be controlled by t...

Страница 47: ...press the Thermostat Key The LCD display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or D...

Страница 48: ...or 1002 P910si Electrode Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62...

Страница 49: ...Configuration 1 Basic Manual HI LO and Manual ON OFF Capabilities 49...

Страница 50: ...and Manual HI LO Optional For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as...

Страница 51: ...I or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the Remote Control Wiring Harness as per the diagrams...

Страница 52: ...Configuration 3 Remote ON OFF Variable HI LO Lights and Fan NOTE FAN IS NOT AVAILABLE ON 42MCVP UNITS ULK LIGHT KIT 52...

Страница 53: ...e department LIGHTING INSTRUCTIONS 1 Stop Read the above safety information on this label 2 Remove batteries from receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 T...

Страница 54: ...ic property 7 feet 2 1m minimum 3 M Clearance above highest point of exit on roof 18 inches 45cm N Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust prod...

Страница 55: ...ttom of fireplace to center of vent see the Framing Your Gas Fireplace section Cut a hole through the wall allowing for a 12 x 12 inside diameter in combustible walls for wall thimble or a 9 diameter...

Страница 56: ...ght of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal verti...

Страница 57: ...te comes in two sizes In the future Wall Thimble mount plate will be smaller than Termination Plate as a running change has been implemented Wall Thimble may need to be trimmed on outside mount plate...

Страница 58: ...Thimble Wall Thimble Wall Thimble 15 3 4 13 5 16 1 3 16 Termination New Wall Thimble Old Termination 13 3 4 13 5 16 3 16 New Wall Thimble New Termination Wall Thimble 13 3 4 New Termination Old Wall...

Страница 59: ...a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingles Both the sides and the lower edge l...

Страница 60: ...Clearances in horizontal venting Straight through roof support configuration b Flex bend configuration c Termination mounting 43ft Z58VT Restrictor Remove for Runs Under 15 Feet 60...

Страница 61: ...ownward vertical vent runs are NOT permitted NOTE MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION Downward vertical vent runs are permitted however Cold Climate Switch Standing Pilot Mode must not b...

Страница 62: ...panded 5 Expanded Z58FK8 Flex Kit 5 8 Dia x 4 Unexpanded 8 Expanded Z58FK20 Flex Kit 5 8 Dia x 10 Unexpanded 20 Expanded Kits are complete with spring stand offs silicone ZDV5FC Flex Connector 5 Diame...

Страница 63: ...hild Safety Screen Large MP42CSSS Child Safety Screen Small Door Glass 42HB 310 Tempered Glass for Decorative Units 42HB 311 Ceramic Glass for Heater Rated Units 42MCVP 315T Tempered Glass for Decorat...

Страница 64: ...0 150MP Hi Temp Millpac Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Bra...

Страница 65: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...

Отзывы: