Using more sound-absorbing materials in decoration can reduce voice echo and improve
acoustics environment.
Adjust the layout to reduce happening of the squeaking.
2.5 RS485
When the DVR receives a camera control command, it transmits that command up the coaxial cable to
the PTZ device. RS485 is a single-direction protocol; the PTZ
device can’t return any data to the unit. To
enable the operation, connect the PTZ device to the RS485 (A,B) input on the DVR (See Figure 2-1).
Since RS485 is disabled by default for each camera, you must enable the PTZ settings first. This series
of DVRs supports multiple protocols such as Pelco-D, Pelco-P.
To connect PTZ devices to the DVR:
1. Connect RS485 A,B on the DVR rear panel
2. Connect the other end of the cable to the proper pins in the connector on the camera.
3. Please follow the instructions to configure a camera to enable each PTZ device on the DVR.