FAN WILL NOT START
1.

   Check that the electricity has been 

turned on at the circuit breaker which had 
probably been turned off during 
installation.

2. 

  Turn off the electricity.  Check all 

connections in the wiring of the fan at the 
ceiling and make sure it follows the 
wiring instructions outlined in this 
manual.

3.

   The fan must be installed at a 

maximum distance of 30 ft. from the 
remote control for proper signal 
transmission between the remote control 
and the fan.

NOISE
Note:

 Always allow a day or two "run-in" 

time for any new fan at medium or high 
speed.  When attempting to diagnose 
noise, listen carefully from several sides 
to try and isolate the location of the noise 
(blade, upper end, motor, light kit, etc.)

1.   

Tighten all screws attaching blades to 

blade arms.  Remember to tighten these 
screws at least once a year because they 
may loosen slowly over time and cause a 
clicking noise.

2. 

  Turn off the power.  Loosen the 

canopy and check that the wiring and/or 
wire nut connectors are not resting against 
the canopy, possibly vibrating while the 
fan is on.

3.

   Use of a standard light rheostat or an 

unapproved fan remote control to control 
the fan speed will always cause an 
annoying "hum".  Many fan motors do not 
work quietly with solid state variable 
speed controls.

4.

   Check that the rubber gasket on the 

mounting bracket has been installed if 
called for in the installation instructions.

5.

   Check that the canopy in not touching 

the ceiling.

6. 

  Check that all screws on the motor 

housing and the bottom housing are tight.

FAN TURNS, BUT DOES NOT MOVE 
MUCH AIR
1.   

The fan may be running in reverse. 

Press the reverse button on transmitter to 
set the fan in forward operation.

2. 

  The distance from the ceiling to the 

blades may be too small. For downrod 
fans, optimal placement would be 8-9 feet 
from the floor.

3.

   The room may contain items which 

obstruct the air flow.

4. 

  The fan may be too small for the size 

of the room.

EXCESSIVE WOBBLE 
Note: 

A small amount of wobble is 

considered acceptable and should not be 
considered a defect.

1. 

  Make certain all blades are tightly 

attached to each blades' respective blade 
arm.

12. TROUBLESHOOTING

REPLACEMENT PARTS

For replacement parts, contact your 
local dealer.

Содержание Windmill 96015 Series

Страница 1: ...ese instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans The Windmill w optional light feature P O Box 961008 Fort Worth TX 76161 817 626 5483...

Страница 2: ...stions regarding the warranty or the procedures for obtaining service please call us at 817 626 5483 Monday thru Friday 8 00 a m 5 00 p m CST technical skill competence or experience of the user 8 Lig...

Страница 3: ...NG CONTACTYOUR DEALER FOR REPLACEMENT OR CALL QUORUM DIRECTLYAND WE WILL MAIL REPLACEMENTS TO YOU IMMEDIATELY 1 To avoid possible electric shock turn off the electricity at the main fuse box or circui...

Страница 4: ...nds 22 7 kg WARNING Support Directly from the Building Structure 3 Secure the outlet box or make sure the existing box is secured directly to the building structure Use appropriate fasteners and build...

Страница 5: ...ASSEMBLY SHOULD BE WORKED AT THE FLOOR 3 Remove the set pin and safety lock clip from the yoke on top of the motor assembly Slide the downrod through the canopy and canopy cover Slide the yoke cover o...

Страница 6: ...e the blade circle Align the holes on the blade deco bars and secure with the blade deco bar screws Screw No 2 as show on Fig 10 Caution Do not tighten screws at this point All screws will be tightene...

Страница 7: ...ow is the time to tighten all the blade and blade arm screws Be sure all screws are fully tightened Be sure not to forget screws No 1 and No 2 Fig 15 6 Lift the fan motor with the blades and place int...

Страница 8: ...he other side 2 Fig 17 Connect the BLACK building supply wire to the BLACK fan wires Connect the WHITE building neutral wire to the WHITE fan neutral wire Connect the COPPER building ground wire to th...

Страница 9: ...o set screws lift canopy cover and attach by turning clockwise Note Adjust the canopy screws as necessary until the canopy and canopy cover are snug Fig 18 8 COMPLETING THE INSTALLATION 9 INSTALLING T...

Страница 10: ...rol will come on when the button is pressed The fan has completed the pairing process with the remote control and is ready for use NOTE A single fan can be controlled with as many as 3 remote controls...

Страница 11: ...Periodically check tightness of all screws securing the blades to the blade arm attachment points A clicking or a rattling noise is a sure indication of loosening screws Since screws will invariably w...

Страница 12: ...against the canopy possibly vibrating while the fan is on 3 Use of a standard light rheostat or an unapproved fan remote control to control the fan speed will always cause an annoying hum Many fan mot...

Отзывы: